Background: Simulating the post-traumatic continuity defect of small human peripheral nerves, we compared the effectiveness of fibrin glue with neurorrhaphy for nerve gap restoration. Methods: In twenty-four male Wistar rats, a fifteen mm defect in one sciatic nerve only was made and immediately repaired with an inverted polarity autograft. According to the used technique, rats were divided into Group A (Control), using traditional neurorrhaphy, and Group B (Study), using fibrine glue sealing; in total, 50% of rats were sacrificed at 16 weeks and 50% at 21 weeks. Before sacrifice, an assessment of motor function was done through Walking Track Analysis and an electroneurophysiological evaluation. After sacrifice, selected muscle mass indexes and the histology of the regenerated nerves were assessed. All data were evaluated by Student's t test for unpaired data. Results: No significant differences were found between the two groups, with only the exception of a relative improvement in the tibialis anterior muscle's number of motor units in the study group. Conclusion: Despite the fact that the use of fibrin glue as a nerve sealant is not superior in terms of functional recovery, its effectiveness is comparable to that of microsurgical repair. Hence, the faster and technically easier glueing technique could deserve broader clinical application.
Zabbia G., Toia F., Coppola F., Cassata G., Cicero L., Giglia G., et al. (2024). Nerve Regeneration after a Nerve Graft in a Rat Model: The Effectiveness of Fibrin Glue. JOURNAL OF PERSONALIZED MEDICINE, 14(5) [10.3390/jpm14050445].
Nerve Regeneration after a Nerve Graft in a Rat Model: The Effectiveness of Fibrin Glue
Zabbia G.;Toia F.;Cassata G.;Giglia G.;Puleio R.;Cordova A.
2024-04-24
Abstract
Background: Simulating the post-traumatic continuity defect of small human peripheral nerves, we compared the effectiveness of fibrin glue with neurorrhaphy for nerve gap restoration. Methods: In twenty-four male Wistar rats, a fifteen mm defect in one sciatic nerve only was made and immediately repaired with an inverted polarity autograft. According to the used technique, rats were divided into Group A (Control), using traditional neurorrhaphy, and Group B (Study), using fibrine glue sealing; in total, 50% of rats were sacrificed at 16 weeks and 50% at 21 weeks. Before sacrifice, an assessment of motor function was done through Walking Track Analysis and an electroneurophysiological evaluation. After sacrifice, selected muscle mass indexes and the histology of the regenerated nerves were assessed. All data were evaluated by Student's t test for unpaired data. Results: No significant differences were found between the two groups, with only the exception of a relative improvement in the tibialis anterior muscle's number of motor units in the study group. Conclusion: Despite the fact that the use of fibrin glue as a nerve sealant is not superior in terms of functional recovery, its effectiveness is comparable to that of microsurgical repair. Hence, the faster and technically easier glueing technique could deserve broader clinical application.File | Dimensione | Formato | |
---|---|---|---|
jpm-14-00445-v2.pdf
accesso aperto
Tipologia:
Versione Editoriale
Dimensione
6.25 MB
Formato
Adobe PDF
|
6.25 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.