In the paper a comparison between radiation-aerodynamic and radiation based evapotranspiration models with an independent dataset of Alfalfa reference evapotranspiration acquired by means a scintillometer is carried out. The satisfactory performance of the selected models is comparable to that showed in earlier investigations. This study also shows that using values of model parameters locally determined, is possible to improve hourly estimation of potential evapotranspiration, as obtained with the scintillometer.

Agnese, C., Cammalleri, C., Minacapilli, M., Provenzano, G., Rallo, G. (2012). Testing approach to estimate hourly reference evapotranspiration with scintillometer measurements under Mediterranean climate. In Atti del XV Convegno Nazionale di Agrometeorologia - Nuovi scenari agro ambientali: fenologia, produzioni agrarie ed avversità (pp. 123-124).

Testing approach to estimate hourly reference evapotranspiration with scintillometer measurements under Mediterranean climate

AGNESE, Carmelo;CAMMALLERI, Carmelo;MINACAPILLI, Mario;PROVENZANO, Giuseppe;
2012-01-01

Abstract

In the paper a comparison between radiation-aerodynamic and radiation based evapotranspiration models with an independent dataset of Alfalfa reference evapotranspiration acquired by means a scintillometer is carried out. The satisfactory performance of the selected models is comparable to that showed in earlier investigations. This study also shows that using values of model parameters locally determined, is possible to improve hourly estimation of potential evapotranspiration, as obtained with the scintillometer.
2012
978-88-555-3175-7
Agnese, C., Cammalleri, C., Minacapilli, M., Provenzano, G., Rallo, G. (2012). Testing approach to estimate hourly reference evapotranspiration with scintillometer measurements under Mediterranean climate. In Atti del XV Convegno Nazionale di Agrometeorologia - Nuovi scenari agro ambientali: fenologia, produzioni agrarie ed avversità (pp. 123-124).
File in questo prodotto:
File Dimensione Formato  
TESTING-APPROACH-TO-ESTIMATE-HOURLY-REFERENCE-EVAPOTRANSPIRATION-WITH-SCINTILLOMETER-MEASUREMENTS-UNDER-MEDITERRANEAN-CLIMATE.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 110.78 kB
Formato Adobe PDF
110.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/64040
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact