PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml, Iomeron, Bracco) and a bolus chaser (40 ml of saline), the scan was completed in <12 s. All coronary segments with a stent were assessed on 64-CT by two observers in consensus and judged as: patent, with intimal hyperplasia (lumen reduction of <50%), with in-stent restenosis (> or =50%), or with in-stent occlusion (100%). The consensus reading was compared with conventional coronary angiography. RESULTS: Four patients were excluded because of insufficient image quality. In the remaining 91, we assessed 102 stents (31 RCA; 10 LM; 54 LAD; 7 CX). In 14 (13.7%) stents, in-stent restenosis (n=8) or in-stent occlusion (n=6) was found. Intimal hyperplasia was detected in 11 (10.8%) stents. The sensitivity and negative predictive value of 64-CT for in-stent occlusion were 100% and 100%, respectively, whereas for all stenoses, >50% they were 92.9% and 98.7%, respectively. CONCLUSIONS: We found that 64-CT has a high diagnostic accuracy for the detection of in-stent restenosis in a selected patient population.

Cademartiri F, P.A. (2007). Diagnostic accuracy of 64-slice CT in the assessment of coronary stents. LA RADIOLOGIA MEDICA, 2007-06.

Diagnostic accuracy of 64-slice CT in the assessment of coronary stents.

LA GRUTTA, Ludovico;RUNZA, Giuseppe;MIDIRI, Massimo;
2007-01-01

Abstract

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml, Iomeron, Bracco) and a bolus chaser (40 ml of saline), the scan was completed in <12 s. All coronary segments with a stent were assessed on 64-CT by two observers in consensus and judged as: patent, with intimal hyperplasia (lumen reduction of <50%), with in-stent restenosis (> or =50%), or with in-stent occlusion (100%). The consensus reading was compared with conventional coronary angiography. RESULTS: Four patients were excluded because of insufficient image quality. In the remaining 91, we assessed 102 stents (31 RCA; 10 LM; 54 LAD; 7 CX). In 14 (13.7%) stents, in-stent restenosis (n=8) or in-stent occlusion (n=6) was found. Intimal hyperplasia was detected in 11 (10.8%) stents. The sensitivity and negative predictive value of 64-CT for in-stent occlusion were 100% and 100%, respectively, whereas for all stenoses, >50% they were 92.9% and 98.7%, respectively. CONCLUSIONS: We found that 64-CT has a high diagnostic accuracy for the detection of in-stent restenosis in a selected patient population.
2007
Cademartiri F, P.A. (2007). Diagnostic accuracy of 64-slice CT in the assessment of coronary stents. LA RADIOLOGIA MEDICA, 2007-06.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/46917
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 12
social impact