Automated inspection systems using industrial robots have been available for several years. The IntACom robot inspection system was developed at TWI Wales and utilizes phased array ultrasonic probes to inspect complex geometries, in particular aerospace composite components. To increase inspection speed and accuracy, off-line path planning is employed to define a series of robotic movements following the surface of a component. To minimize influences of refraction at the component interface and effects of anisotropy, the ultrasonic probe must be kept perpendicular to the surface throughout the inspection. Deviations between the actual component and computer model used for path-planning result in suboptimal alignment and a subsequent reduction in the quality of the ultrasonic echo signal. In this work we demonstrate methods for using the ultrasonic echo signals to adapt a robotic path to achieve a minimal variation in the reflected surface echo. The component surface is imaged using phased array probes to calculate a sparse 3D point cloud with estimated normal directions. This is done through a preliminary alignment path covering approximately 25% of the total surface to minimize the impact on overall inspection time. The data is then compared to the expected geometry and deviations are minimized using least-squares optimization. Compared to manual alignment techniques, this method shows a reduction in surface amplitude variation of up to 32%, indicating that the robot is following the surface of the component more accurately.

Riise J., Mineo C., Pierce S.G., Nicholson P.I., Cooper I. (2019). Adapting robot paths for automated NDT of complex structures using ultrasonic alignment. In AIP Conference Proceedings. 2 HUNTINGTON QUADRANGLE, STE 1NO1, MELVILLE, NY 11747-4501 USA : American Institute of Physics Inc. [10.1063/1.5099756].

Adapting robot paths for automated NDT of complex structures using ultrasonic alignment

Mineo C.;
2019-01-01

Abstract

Automated inspection systems using industrial robots have been available for several years. The IntACom robot inspection system was developed at TWI Wales and utilizes phased array ultrasonic probes to inspect complex geometries, in particular aerospace composite components. To increase inspection speed and accuracy, off-line path planning is employed to define a series of robotic movements following the surface of a component. To minimize influences of refraction at the component interface and effects of anisotropy, the ultrasonic probe must be kept perpendicular to the surface throughout the inspection. Deviations between the actual component and computer model used for path-planning result in suboptimal alignment and a subsequent reduction in the quality of the ultrasonic echo signal. In this work we demonstrate methods for using the ultrasonic echo signals to adapt a robotic path to achieve a minimal variation in the reflected surface echo. The component surface is imaged using phased array probes to calculate a sparse 3D point cloud with estimated normal directions. This is done through a preliminary alignment path covering approximately 25% of the total surface to minimize the impact on overall inspection time. The data is then compared to the expected geometry and deviations are minimized using least-squares optimization. Compared to manual alignment techniques, this method shows a reduction in surface amplitude variation of up to 32%, indicating that the robot is following the surface of the component more accurately.
2019
978-073541832-5
Riise J., Mineo C., Pierce S.G., Nicholson P.I., Cooper I. (2019). Adapting robot paths for automated NDT of complex structures using ultrasonic alignment. In AIP Conference Proceedings. 2 HUNTINGTON QUADRANGLE, STE 1NO1, MELVILLE, NY 11747-4501 USA : American Institute of Physics Inc. [10.1063/1.5099756].
File in questo prodotto:
File Dimensione Formato  
QNDE_AlignmentPaper.pdf

accesso aperto

Tipologia: Pre-print
Dimensione 821.28 kB
Formato Adobe PDF
821.28 kB Adobe PDF Visualizza/Apri
1.5099756.pdf

accesso aperto

Descrizione: Articolo completo
Tipologia: Versione Editoriale
Dimensione 1.68 MB
Formato Adobe PDF
1.68 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/425446
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact