Two versions of a PPG/ECG combined system have been realized and tested. In a first version a multisite system has been equipped by integrating 3 PPG optodes and 3 ECG leads, whereas in another setup a portable version has been carried out. Both versions have been realized by equipping the optical probes with SiPM detectors. SiPM technology is expected to bring relevant advantages in PPG systems and overcome the limitations of physiological information extracted by state of the art PPG, such as poor sensitivity of detectors used for backscattered light detection and motion artifacts seriously affecting the measurements repeatability and pulse waveform stability. This contribution presents the intermediate results of development in the frame of the European H2020-ECSEL Project ASTONISH (n. 692470), including SiPM based PPG optodes, and the acquisition electronic components used for simultaneous recording of both PPG/ECG signals. The accurate monitoring of dynamic changes of physiological data through a non-invasive integrated system, including hemodynamic parameters (e.g. heart rate, tissue perfusion etc.) and heart electrical activity can play an important role in a wide variety of applications (e.g. healthcare, fitness and cardiovascular disease). In this work we describe also a method to process PPG waveform according to a PPG process pipeline for pattern recognition. Some examples of PPG waveform signal analysis and the preliminary results of acquisitions obtained through the intermediate demonstrator systems have been reported.

Vinciguerra, V., Ambra, E., Maddiona, L., Romeo, M., Mazzillo, M., Rundo, F., et al. (2019). PPG/ECG multisite combo system based on SiPM technology. In Lecture Notes in Electrical Engineering (pp. 353-360). Springer Verlag [10.1007/978-3-030-04324-7_44].

PPG/ECG multisite combo system based on SiPM technology

Busacca, Alessandro;Guarino, Saverio;Parisi, Antonino;Pernice, Riccardo
2019-01-01

Abstract

Two versions of a PPG/ECG combined system have been realized and tested. In a first version a multisite system has been equipped by integrating 3 PPG optodes and 3 ECG leads, whereas in another setup a portable version has been carried out. Both versions have been realized by equipping the optical probes with SiPM detectors. SiPM technology is expected to bring relevant advantages in PPG systems and overcome the limitations of physiological information extracted by state of the art PPG, such as poor sensitivity of detectors used for backscattered light detection and motion artifacts seriously affecting the measurements repeatability and pulse waveform stability. This contribution presents the intermediate results of development in the frame of the European H2020-ECSEL Project ASTONISH (n. 692470), including SiPM based PPG optodes, and the acquisition electronic components used for simultaneous recording of both PPG/ECG signals. The accurate monitoring of dynamic changes of physiological data through a non-invasive integrated system, including hemodynamic parameters (e.g. heart rate, tissue perfusion etc.) and heart electrical activity can play an important role in a wide variety of applications (e.g. healthcare, fitness and cardiovascular disease). In this work we describe also a method to process PPG waveform according to a PPG process pipeline for pattern recognition. Some examples of PPG waveform signal analysis and the preliminary results of acquisitions obtained through the intermediate demonstrator systems have been reported.
2019
Vinciguerra, V., Ambra, E., Maddiona, L., Romeo, M., Mazzillo, M., Rundo, F., et al. (2019). PPG/ECG multisite combo system based on SiPM technology. In Lecture Notes in Electrical Engineering (pp. 353-360). Springer Verlag [10.1007/978-3-030-04324-7_44].
File in questo prodotto:
File Dimensione Formato  
2019_Vinciguerra_LNEE_PPGECG Multisite Combo System Based on SiPM Technology.pdf

Solo gestori archvio

Descrizione: Articolo principale
Dimensione 490.28 kB
Formato Adobe PDF
490.28 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
2019_Vinciguerra_LNEE_CNS2018_postprint.pdf

accesso aperto

Descrizione: pdf
Tipologia: Post-print
Dimensione 500.97 kB
Formato Adobe PDF
500.97 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/351675
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? ND
social impact