The main aim of this work is to evaluate how the use of an active protection method, consisting in an improved forced longitudinal ventilation system, can determine a positive impact on heat extraction and people evacuation time in a tunnel fire scenario, by considering a case study which simulations are based on a real gallery.
Laura Cirrincione, G.S. (2019). Tunnel fire active protection: improving ventilation system. JOURNAL OF PHYSICS. CONFERENCE SERIES, 1224 [10.1088/1742-6596/1224/1/012005].
Tunnel fire active protection: improving ventilation system
Laura Cirrincione
;Gianluca Scaccianoce;Gianfranco Rizzo
2019-01-01
Abstract
The main aim of this work is to evaluate how the use of an active protection method, consisting in an improved forced longitudinal ventilation system, can determine a positive impact on heat extraction and people evacuation time in a tunnel fire scenario, by considering a case study which simulations are based on a real gallery.File in questo prodotto: