The study aims at applying of Load Match and Grid Interaction indexes to a Net Zero Energy Building in order to optimize the performances of its energy systems. The case study is a modular prefabricated house that uses solar energy (photovoltaic) and natural gas (Fuel Cell) as energy sources and equipped with an Energy Management System addressing the optimal energy use.

Ferraro, M., Sergi, F., Antonucci, V., Guarino, F., Tumminia, G., Cellura, M. (2016). Load match and grid interaction optimization of a net zero energy building through electricity storage: An Italian case-study. In 2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC). Institute of Electrical and Electronics Engineers Inc. [10.1109/EEEIC.2016.7555812].

Load match and grid interaction optimization of a net zero energy building through electricity storage: An Italian case-study

GUARINO, Francesco;Tumminia, Giovanni;CELLURA, Maurizio
2016-01-01

Abstract

The study aims at applying of Load Match and Grid Interaction indexes to a Net Zero Energy Building in order to optimize the performances of its energy systems. The case study is a modular prefabricated house that uses solar energy (photovoltaic) and natural gas (Fuel Cell) as energy sources and equipped with an Energy Management System addressing the optimal energy use.
giu-2016
16th International Conference on Environment and Electrical Engineering, EEEIC 2016
Florence, Italy
6 - 8 June 2016
2016
5
Online
https://ieeexplore.ieee.org/document/7555812
Ferraro, M., Sergi, F., Antonucci, V., Guarino, F., Tumminia, G., Cellura, M. (2016). Load match and grid interaction optimization of a net zero energy building through electricity storage: An Italian case-study. In 2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC). Institute of Electrical and Electronics Engineers Inc. [10.1109/EEEIC.2016.7555812].
Proceedings (atti dei congressi)
Ferraro, M.; Sergi, F.; Antonucci, V.; Guarino, F.; Tumminia, G.; Cellura, M.
File in questo prodotto:
File Dimensione Formato  
Load Match and Grid Interaction Optimization of a Net Zero Energy Building Through Electricity Storage An Italian case study.pdf

Solo gestori archvio

Dimensione 1.39 MB
Formato Adobe PDF
1.39 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/213150
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 3
social impact