Radon risk assessment is carried out with accurate measurements with active or passive instrumentation. All radon detectors must be calibrated and tested using a radon chamber containing a known concentration of radon produced by specific sources of 226Ra. Some of the chambers can also be used to test the response of detectors as a function of environmental conditions. In this case, it can be inferred a calibration curve with respect to changing of the parameter considered. For this aim, a new chamber radon was designed and realized to perform both calibration of instruments and to study the detector response in a large range of variation of the environmental parameters (pressure, 700 - 1100 mbar; temperature, 5-50 ◦C; humidity, 10-90%). The experiments conducted to study the influence of environmental parameters on the detector response, in terms of variation of radon concentration and equilibrium factor, have shown flexibility and ease of use of the chamber.

Compagno, A., Parlato, A., Rizzo, S., Tomarchio, E. (2010). A chamber to test the response of radon detectors to changing environmental conditions. In 6th Conference on Protection Against Radon at Home and at Work BOOK OF ABSTRACTS (pp.38-38). Praga : Editors: Tomas Urban, Katerina Rovenska, Jiri Martincik.

A chamber to test the response of radon detectors to changing environmental conditions

PARLATO, Aldo;RIZZO, Salvatore;TOMARCHIO, Elio Angelo
2010-01-01

Abstract

Radon risk assessment is carried out with accurate measurements with active or passive instrumentation. All radon detectors must be calibrated and tested using a radon chamber containing a known concentration of radon produced by specific sources of 226Ra. Some of the chambers can also be used to test the response of detectors as a function of environmental conditions. In this case, it can be inferred a calibration curve with respect to changing of the parameter considered. For this aim, a new chamber radon was designed and realized to perform both calibration of instruments and to study the detector response in a large range of variation of the environmental parameters (pressure, 700 - 1100 mbar; temperature, 5-50 ◦C; humidity, 10-90%). The experiments conducted to study the influence of environmental parameters on the detector response, in terms of variation of radon concentration and equilibrium factor, have shown flexibility and ease of use of the chamber.
Settore ING-IND/20 - Misure E Strumentazione Nucleari
set-2010
6th Conference on Protection Against Radon at Home and at Work (RADON-2010),
Prague, Czech Republic
13-17 September, 2010
2010
1
Compagno, A., Parlato, A., Rizzo, S., Tomarchio, E. (2010). A chamber to test the response of radon detectors to changing environmental conditions. In 6th Conference on Protection Against Radon at Home and at Work BOOK OF ABSTRACTS (pp.38-38). Praga : Editors: Tomas Urban, Katerina Rovenska, Jiri Martincik.
Proceedings (atti dei congressi)
Compagno, A; Parlato, A; Rizzo, S; Tomarchio, E
File in questo prodotto:
File Dimensione Formato  
Abstract RADON 2010.docx

Solo gestori archvio

Descrizione: Abstract
Dimensione 19.44 kB
Formato Microsoft Word XML
19.44 kB Microsoft Word XML   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/98276
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 2
social impact