After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons learned for the development and calibration programs of filters for X-ray detectors in future Astronomy missions.

Barbera, M., Agnello, S., Buscarino, G., Collura, A., Gastaldello, F., La Palombara, N., et al. (2013). Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters. In Proceedings of the SPIE, Volume 8859, id. 885914 (pp.1-12). Oswald H. Siegmund [10.1117/12.2030896].

Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters

BARBERA, Marco;AGNELLO, Simonpietro;BUSCARINO, Gianpiero;SCIORTINO, Luisa;
2013-01-01

Abstract

After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons learned for the development and calibration programs of filters for X-ray detectors in future Astronomy missions.
Settore FIS/05 - Astronomia E Astrofisica
UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XVIII
apr-2013
2013
12
A stampa
ISBN: 978-081949709-3
Barbera, M., Agnello, S., Buscarino, G., Collura, A., Gastaldello, F., La Palombara, N., et al. (2013). Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters. In Proceedings of the SPIE, Volume 8859, id. 885914 (pp.1-12). Oswald H. Siegmund [10.1117/12.2030896].
Proceedings (atti dei congressi)
Barbera, M; Agnello, S; Buscarino, G; Collura, A; Gastaldello, F; La Palombara, N; Lo Cicero, U; Tiengo, A; Sciortino, L; Varisco, S; Venezia, AM
File in questo prodotto:
File Dimensione Formato  
885914.pdf

Solo gestori archvio

Descrizione: Main Article
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/85411
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact