The paper proposes a methodology for tracing active power flow which also considers power losses partition. It requires the partition of the active power losses in each line over different flow components. Then, the differences arising from the selection of different criteria for the allocation of the mutual terms (deriving from the non-linearity of losses) are investigated. Power flows tracing and losses allocation at each generator (or load) must be carried out simultaneously; therefore, a suitable order is required for the analysis of nodes and lines in a network. A procedure for the direct evaluation of all the components of the power flows and of the losses in the lines assigned to the generators is presented. The results over the 30 buses IEEE network are reported and a comparison with results obtained using other methodologies allows to formulate some interesting conclusions.
Augugliaro, A., Dusonchet, L., Favuzza, S., Ippolito, M.G., Riva Sanseverino, E. (2012). INFLUENCE OF LOSSES PARTITION CRITERIA ON POWER FLOW TRACING. In Proceedingss of 2nd IEEE International Conference & exhibition ENERGYCON 2012 (pp. 310-317). IEEE [10.1109/EnergyCon.2012.6347773].
INFLUENCE OF LOSSES PARTITION CRITERIA ON POWER FLOW TRACING
AUGUGLIARO, Antonino;DUSONCHET, Luigi;FAVUZZA, Salvatore;IPPOLITO, Mariano Giuseppe;RIVA SANSEVERINO, Eleonora
2012-01-01
Abstract
The paper proposes a methodology for tracing active power flow which also considers power losses partition. It requires the partition of the active power losses in each line over different flow components. Then, the differences arising from the selection of different criteria for the allocation of the mutual terms (deriving from the non-linearity of losses) are investigated. Power flows tracing and losses allocation at each generator (or load) must be carried out simultaneously; therefore, a suitable order is required for the analysis of nodes and lines in a network. A procedure for the direct evaluation of all the components of the power flows and of the losses in the lines assigned to the generators is presented. The results over the 30 buses IEEE network are reported and a comparison with results obtained using other methodologies allows to formulate some interesting conclusions.File | Dimensione | Formato | |
---|---|---|---|
Articolo pubblicato.pdf
Solo gestori archvio
Descrizione: Articolo completo
Tipologia:
Versione Editoriale
Dimensione
381.65 kB
Formato
Adobe PDF
|
381.65 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.