The objective of this study, concerning the soil–structure interaction of shallow reinforced concrete foundations of wind towers with circular cross-sections, was determination in a closed form of the monotonic moment–rotation curve of the soil–foundation complex. This study was based on elastic and plastic analyses of shallow rigid foundations assuming a Winkler soil type including the flexibility of the foundation in the elastic range and the nature of the soil (cohesive and non-cohesive types) through corrective factors of the constant of the Winkler model. The flexibility of the foundations influences the moment–rotation response through the initial rotational stiffness with a coefficient between 1 and 0.7 for a width-to-span ratio between 5 and 2. The nature of the soil is considered through corrective factors of 0.75 and 1.3 of the Winkler constant for cohesive and non-cohesive soil, respectively. Analyses carried out stressed that a possible design valued to be adopted in a steel wind tower with shallow foundations is a diameter of the steel tube 1/15 of the height of the tower, a diameter of foundation 0.75 of the length, and a depth of foundation 1/10 of the diameter and thickness of steel tower ratio diameter equal to 1/10. In this range it was observed that the effects of the soil-to-foundation interaction in the elastic range influences the critical length in the stability of the steel wind tower, with values between 2.5 and 2 (column fixed at the base) in a range of Winkler constant between 0.1 and 1 daN/cm3. Finally, an experimental validation of the proposed model was carried out with the data available from the literature.
CAMPIONE, G. (2024). Influence of Shallow Foundations on the Response of Steel Wind Towers. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 22, 1309-1319 [10.1007/s40999-023-00936-z].
Influence of Shallow Foundations on the Response of Steel Wind Towers
CAMPIONE,G
2024-07-03
Abstract
The objective of this study, concerning the soil–structure interaction of shallow reinforced concrete foundations of wind towers with circular cross-sections, was determination in a closed form of the monotonic moment–rotation curve of the soil–foundation complex. This study was based on elastic and plastic analyses of shallow rigid foundations assuming a Winkler soil type including the flexibility of the foundation in the elastic range and the nature of the soil (cohesive and non-cohesive types) through corrective factors of the constant of the Winkler model. The flexibility of the foundations influences the moment–rotation response through the initial rotational stiffness with a coefficient between 1 and 0.7 for a width-to-span ratio between 5 and 2. The nature of the soil is considered through corrective factors of 0.75 and 1.3 of the Winkler constant for cohesive and non-cohesive soil, respectively. Analyses carried out stressed that a possible design valued to be adopted in a steel wind tower with shallow foundations is a diameter of the steel tube 1/15 of the height of the tower, a diameter of foundation 0.75 of the length, and a depth of foundation 1/10 of the diameter and thickness of steel tower ratio diameter equal to 1/10. In this range it was observed that the effects of the soil-to-foundation interaction in the elastic range influences the critical length in the stability of the steel wind tower, with values between 2.5 and 2 (column fixed at the base) in a range of Winkler constant between 0.1 and 1 daN/cm3. Finally, an experimental validation of the proposed model was carried out with the data available from the literature.File | Dimensione | Formato | |
---|---|---|---|
s40999-023-00936-z (1).pdf
accesso aperto
Tipologia:
Versione Editoriale
Dimensione
1.01 MB
Formato
Adobe PDF
|
1.01 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.