In this work, we propose a low-cost Smart and Healthy Intelligent Room System (SHIRS), able to monitor Indoor Air Quality (IAQ) by enhancing edge-based computation. SHIRS exploits the ability to run Machine Learning (ML) algorithms to infer humans presence (headcount) from environmental data analysis. Experimental results show the validity of the proposed approach, demonstrate the potential of edge-based computing and push towards the adoption of smart integrated Cloud-IoT frameworks for environmental monitoring and control.

Cicceri G., Scaffidi C., Benomar Z., Distefano S., Puliafito A., Tricomi G., et al. (2020). Smart Healthy Intelligent Room: Headcount through Air Quality Monitoring. In Proceedings - 2020 IEEE International Conference on Smart Computing, SMARTCOMP 2020 (pp. 320-325). 345 E 47TH ST, NEW YORK, NY 10017 USA : Institute of Electrical and Electronics Engineers Inc. [10.1109/SMARTCOMP50058.2020.00071].

Smart Healthy Intelligent Room: Headcount through Air Quality Monitoring

Cicceri G.
Primo
;
2020-11-06

Abstract

In this work, we propose a low-cost Smart and Healthy Intelligent Room System (SHIRS), able to monitor Indoor Air Quality (IAQ) by enhancing edge-based computation. SHIRS exploits the ability to run Machine Learning (ML) algorithms to infer humans presence (headcount) from environmental data analysis. Experimental results show the validity of the proposed approach, demonstrate the potential of edge-based computing and push towards the adoption of smart integrated Cloud-IoT frameworks for environmental monitoring and control.
6-nov-2020
Cicceri G., Scaffidi C., Benomar Z., Distefano S., Puliafito A., Tricomi G., et al. (2020). Smart Healthy Intelligent Room: Headcount through Air Quality Monitoring. In Proceedings - 2020 IEEE International Conference on Smart Computing, SMARTCOMP 2020 (pp. 320-325). 345 E 47TH ST, NEW YORK, NY 10017 USA : Institute of Electrical and Electronics Engineers Inc. [10.1109/SMARTCOMP50058.2020.00071].
File in questo prodotto:
File Dimensione Formato  
Smart_Healthy_Intelligent_Room_Headcount_through_Air_Quality_Monitoring.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 399.75 kB
Formato Adobe PDF
399.75 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/669468
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact