In this paper, a performance comparison between two focusing systems, using a Periodic Permanent Magnet (PPM) and a Halbach Array (HA) for a circular beam Traveling Wave Tube (TWT) is reported. Magneto-static simulations demonstrate that HA is capable to generate the same magnetic field of the PPM configuration, with a reduction of the overall weight and radius of the magnetic circuit by a factor equal to 58% and 32%, respectively. These results pave the way for the exploitation of HA in circular beam-based TWTs and Klystrons for applications where weight reduction is fundamental.

Paterna, G., Comparato, G., Lipari, G., Traina, E., Muratore, A., Busacca, A., et al. (2024). Comparison Between Halbach Array and Periodic Permanent Magnet Circuit Configuration. In 2024 Joint International Vacuum Electronics Conference and International Vacuum Electron Sources Conference (IVEC + IVESC) (pp. 01-02) [10.1109/ivecivesc60838.2024.10694882].

Comparison Between Halbach Array and Periodic Permanent Magnet Circuit Configuration

Paterna, Giuseppe;Comparato, Giorgia;Lipari, Giuseppe;Traina, Eleonora;Muratore, Antonino;Busacca, Alessandro;Livreri, Patrizia;Stivala, Salvatore
2024-01-01

Abstract

In this paper, a performance comparison between two focusing systems, using a Periodic Permanent Magnet (PPM) and a Halbach Array (HA) for a circular beam Traveling Wave Tube (TWT) is reported. Magneto-static simulations demonstrate that HA is capable to generate the same magnetic field of the PPM configuration, with a reduction of the overall weight and radius of the magnetic circuit by a factor equal to 58% and 32%, respectively. These results pave the way for the exploitation of HA in circular beam-based TWTs and Klystrons for applications where weight reduction is fundamental.
2024
979-8-3503-4870-5
Paterna, G., Comparato, G., Lipari, G., Traina, E., Muratore, A., Busacca, A., et al. (2024). Comparison Between Halbach Array and Periodic Permanent Magnet Circuit Configuration. In 2024 Joint International Vacuum Electronics Conference and International Vacuum Electron Sources Conference (IVEC + IVESC) (pp. 01-02) [10.1109/ivecivesc60838.2024.10694882].
File in questo prodotto:
File Dimensione Formato  
Comparison_Between_Halbach_Array_and_Periodic_Permanent_Magnet_Circuit_Configuration.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 762.98 kB
Formato Adobe PDF
762.98 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/662237
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact