The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with 10B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 109 to 1014 nth cm-2. The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those using only alanine. Moreover, a negligible correction for the gamma contribution, measured with TL detectors, almost insensitive to thermal neutrons, was necessary. Therefore, a simultaneous analysis of our TL and ESR detectors allows discrimination between thermal neutron and gamma doses, as required in BNCT.
BARTOLOTTA A, D'OCA MC, LO GIUDICE B, BRAI M, BORIO R, FORINI N, et al. (2004). Combined TL and 10B-alanine ESR dosimetry for BNCT. RADIATION PROTECTION DOSIMETRY, 110(1-4), 627-630 [10.1093/rpd/nch110].
Combined TL and 10B-alanine ESR dosimetry for BNCT
BARTOLOTTA, Antonio;D'OCA, Maria Cristina;BRAI, Maria;
2004-01-01
Abstract
The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with 10B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 109 to 1014 nth cm-2. The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those using only alanine. Moreover, a negligible correction for the gamma contribution, measured with TL detectors, almost insensitive to thermal neutrons, was necessary. Therefore, a simultaneous analysis of our TL and ESR detectors allows discrimination between thermal neutron and gamma doses, as required in BNCT.File | Dimensione | Formato | |
---|---|---|---|
Bartolotta-2004-Combined-tl-and-b-alanine-esr-dosim.pdf
Solo gestori archvio
Dimensione
106.13 kB
Formato
Adobe PDF
|
106.13 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.