The home automation system to control the climatic health in confined environments is the subject of this article. The standard UNI EN ISO 7730:2006 classifies the conditions of moderate confined environments by three categories according to the PMV index. The comfort sensation is mainly affected by four variables: air temperature, mean radiant temperature, air velocity, relative humidity. They are all mechanical and thermal quantities therefore they are measured through the same measurement method. In evaluating the PMV index two more variables are taken into account: metabolism and clothing insulation. They can be evaluated by different accuracy levels. Their indirect measure is subjected to more uncertainty than the above four measuring parameters and the distribution is typically non-Gaussian. The paper analyses the uncertainty in PMV measuring through the Monte Carlo simulation. The proposed study identifies the different weight of independent variables showing as their uncertainty, particularly those referred to metabolism and clothing insulation, affects considerably the final values for classifying the moderate environments.

Bertetto, A.M., Cadeddu, A., Niccolini, G., Di Pilla, L., Ricciu, R. (2015). Home automation systems and PMV classification for moderate confined environments. In 2014 23rd International Conference on Robotics in Alpe-Adria-Danube Region (RAAD). IEEE Institute of Electrical and Electronics Engineers [10.1109/raad.2014.7002277].

Home automation systems and PMV classification for moderate confined environments

Di Pilla, Lorenza
Membro del Collaboration Group
;
2015-01-01

Abstract

The home automation system to control the climatic health in confined environments is the subject of this article. The standard UNI EN ISO 7730:2006 classifies the conditions of moderate confined environments by three categories according to the PMV index. The comfort sensation is mainly affected by four variables: air temperature, mean radiant temperature, air velocity, relative humidity. They are all mechanical and thermal quantities therefore they are measured through the same measurement method. In evaluating the PMV index two more variables are taken into account: metabolism and clothing insulation. They can be evaluated by different accuracy levels. Their indirect measure is subjected to more uncertainty than the above four measuring parameters and the distribution is typically non-Gaussian. The paper analyses the uncertainty in PMV measuring through the Monte Carlo simulation. The proposed study identifies the different weight of independent variables showing as their uncertainty, particularly those referred to metabolism and clothing insulation, affects considerably the final values for classifying the moderate environments.
2015
Settore ING-IND/11 - Fisica Tecnica Ambientale
9788022742191
Bertetto, A.M., Cadeddu, A., Niccolini, G., Di Pilla, L., Ricciu, R. (2015). Home automation systems and PMV classification for moderate confined environments. In 2014 23rd International Conference on Robotics in Alpe-Adria-Danube Region (RAAD). IEEE Institute of Electrical and Electronics Engineers [10.1109/raad.2014.7002277].
File in questo prodotto:
File Dimensione Formato  
9 PMV RAAD.pdf

Solo gestori archvio

Tipologia: Post-print
Dimensione 981.27 kB
Formato Adobe PDF
981.27 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/627955
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact