This study, for the first time, evaluated the safety and efficacy of a new natural-based topical gel containing a spirulina extract. This photoconverter gel generates fluorescent light energy (FLE) via a red LED light device, which is proven to be effective for age control of facial skin. This was a one-centre, observational, uncontrolled pilot trial. Eight healthy female subjects aged 35 to 65 years old, with Fitzpatrick skin types II–V were recruited. The duration of the study was five treatment sessions of one treatment every seven days, with a final follow-up at one month after the last treatment session. The images and the related data were acquired with the SONY® Mod. DSCRX10M3, the Canfield VISIA Facial Imaging System®, and QUANTIFICARE 3D® analysis. Patient compliance was excellent (100%) and the treatment was described as warm and pleasant by the patients. After 30 days, VISIA parameters such as wrinkles, texture, red areas, and Trueskin Age® had improved. The safety and efficacy of the FLE treatment assessed in this trial were achieved for overall rejuvenation of facial skin, focusing on wrinkles evaluated via the specific VISIA algorithms.

Scarcella G., Tardugno R., Crupi P., Muraglia M., Clodoveo M.L., Corbo F. (2023). Fluorescent Light Energy (FLE) Generated through Red LED Light and a Natural Photoconverter Gel as a New, Non-Invasive Approach for Facial Age Control: A Pilot Study. COSMETICS, 10(3) [10.3390/cosmetics10030074].

Fluorescent Light Energy (FLE) Generated through Red LED Light and a Natural Photoconverter Gel as a New, Non-Invasive Approach for Facial Age Control: A Pilot Study

Crupi P.;
2023-05-09

Abstract

This study, for the first time, evaluated the safety and efficacy of a new natural-based topical gel containing a spirulina extract. This photoconverter gel generates fluorescent light energy (FLE) via a red LED light device, which is proven to be effective for age control of facial skin. This was a one-centre, observational, uncontrolled pilot trial. Eight healthy female subjects aged 35 to 65 years old, with Fitzpatrick skin types II–V were recruited. The duration of the study was five treatment sessions of one treatment every seven days, with a final follow-up at one month after the last treatment session. The images and the related data were acquired with the SONY® Mod. DSCRX10M3, the Canfield VISIA Facial Imaging System®, and QUANTIFICARE 3D® analysis. Patient compliance was excellent (100%) and the treatment was described as warm and pleasant by the patients. After 30 days, VISIA parameters such as wrinkles, texture, red areas, and Trueskin Age® had improved. The safety and efficacy of the FLE treatment assessed in this trial were achieved for overall rejuvenation of facial skin, focusing on wrinkles evaluated via the specific VISIA algorithms.
9-mag-2023
Settore AGR/15 - Scienze E Tecnologie Alimentari
Scarcella G., Tardugno R., Crupi P., Muraglia M., Clodoveo M.L., Corbo F. (2023). Fluorescent Light Energy (FLE) Generated through Red LED Light and a Natural Photoconverter Gel as a New, Non-Invasive Approach for Facial Age Control: A Pilot Study. COSMETICS, 10(3) [10.3390/cosmetics10030074].
File in questo prodotto:
File Dimensione Formato  
cosmetics-10-00074.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 3.63 MB
Formato Adobe PDF
3.63 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/622515
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact