In this paper three diagnostic procedures, based on on the vibration, current and instantaneous power monitoring for the detection and monitoring of incipient faults as cracks or bar breaks on squirrel cage motors are briefly reminded. The experimental investigations, carried out at the SDESLab (Sustainable Development Energy Savings Laboratory) of the University of Palermo in order to underline merits and drawbacks of the methods applied to the same die cast squirrel cage induction motor, are presented. The results of the investigations confirmed the effectiveness of the diagnostic procedures here considered.

Di Tommaso, A.O., Miceli, R., Ricco Galluzzo, G. (2011). Monitoring and Diagnosis of Failures in Squirrel-Cage Induction Motors Due to Cracked or Broken Bars. In Proceedings of the 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives. Bologna : IEEE [10.1109/DEMPED.2011.6063599].

Monitoring and Diagnosis of Failures in Squirrel-Cage Induction Motors Due to Cracked or Broken Bars

DI TOMMASO, Antonino Oscar;MICELI, Rosario;RICCO GALLUZZO, Giuseppe
2011-01-01

Abstract

In this paper three diagnostic procedures, based on on the vibration, current and instantaneous power monitoring for the detection and monitoring of incipient faults as cracks or bar breaks on squirrel cage motors are briefly reminded. The experimental investigations, carried out at the SDESLab (Sustainable Development Energy Savings Laboratory) of the University of Palermo in order to underline merits and drawbacks of the methods applied to the same die cast squirrel cage induction motor, are presented. The results of the investigations confirmed the effectiveness of the diagnostic procedures here considered.
Settore ING-IND/32 - Convertitori, Macchine E Azionamenti Elettrici
6-set-2011
8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives (SDEMPED’2011)
Bologna, Italy
September 5-8, 2011
8
2011
00
Online
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?tp=&arnumber=6063599&queryText%3DMonitoring+and+Diagnosis+of+Failures+in+Squirrel-Cage+Induction+Motors+Due+to+Cracked+or+Broken+Bars
IEEE Catalog Number: CFP11SDE-USB
Di Tommaso, A.O., Miceli, R., Ricco Galluzzo, G. (2011). Monitoring and Diagnosis of Failures in Squirrel-Cage Induction Motors Due to Cracked or Broken Bars. In Proceedings of the 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives. Bologna : IEEE [10.1109/DEMPED.2011.6063599].
Proceedings (atti dei congressi)
Di Tommaso, AO; Miceli, R; Ricco Galluzzo, G
File in questo prodotto:
File Dimensione Formato  
309.pdf

Solo gestori archvio

Dimensione 1.67 MB
Formato Adobe PDF
1.67 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/60550
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? ND
social impact