Tuned Mass Dampers (TMD) have been widely used in the passive vibration control of engineering structures, both under wind and seismic loads. Under wind loads, a proper frequency tuning ensures a significant response reduction of the primary structure. While under wind loads the structure is likely to remain in the elastic range of behaviour, when large earthquakes occur it can experience inelastic deformations and damage, with a consequent de-tuning effect. In this paper, nonconventional TMDs with large mass ratios, realized through Interstory Isolation Systems (IIS), are considered and the influence of the inelastic behaviour of the primary system on the overall structure response is analysed. In detail, IIS is employed for retrofitting existing masonry buildings through a vertical extension, isolated at its base and built up on the roof of the existing structure. Pivot-type hysteretic models are used to grasp the mechanical behaviour of the masonry structure. Based on a case-study building, time history analyses on 3D Finite Element models are implemented. The results of nonlinear time history analyses show that in the building with the vertical extension both displacements and hysteretic energy dissipated by the masonry piers, are lower than in the as-is building, confirming that, although a de-tuning effect can occur, the inelastic engagement of the original structure is significantly reduced.
Esposito, F., Faiella, D., Argenziano, M., Brandonisio, G., Mele, E. (2023). The Effect of Nonlinear Response of the Primary System in Nonconventional TMDs. In G.P. Cimellaro (a cura di), Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures 17th World Conference on Seismic Isolation (17WCSI) (pp. 546-556). GEWERBESTRASSE 11, CHAM, CH-6330, SWITZERLAND : SPRINGER INTERNATIONAL PUBLISHING AG [10.1007/978-3-031-21187-4_46].
The Effect of Nonlinear Response of the Primary System in Nonconventional TMDs
Argenziano, M;
2023-01-01
Abstract
Tuned Mass Dampers (TMD) have been widely used in the passive vibration control of engineering structures, both under wind and seismic loads. Under wind loads, a proper frequency tuning ensures a significant response reduction of the primary structure. While under wind loads the structure is likely to remain in the elastic range of behaviour, when large earthquakes occur it can experience inelastic deformations and damage, with a consequent de-tuning effect. In this paper, nonconventional TMDs with large mass ratios, realized through Interstory Isolation Systems (IIS), are considered and the influence of the inelastic behaviour of the primary system on the overall structure response is analysed. In detail, IIS is employed for retrofitting existing masonry buildings through a vertical extension, isolated at its base and built up on the roof of the existing structure. Pivot-type hysteretic models are used to grasp the mechanical behaviour of the masonry structure. Based on a case-study building, time history analyses on 3D Finite Element models are implemented. The results of nonlinear time history analyses show that in the building with the vertical extension both displacements and hysteretic energy dissipated by the masonry piers, are lower than in the as-is building, confirming that, although a de-tuning effect can occur, the inelastic engagement of the original structure is significantly reduced.File | Dimensione | Formato | |
---|---|---|---|
ASSISI_Esposito et al.pdf
Solo gestori archvio
Descrizione: ahead of print
Tipologia:
Versione Editoriale
Dimensione
1.65 MB
Formato
Adobe PDF
|
1.65 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
978-3-031-21187-4_46.pdf
Solo gestori archvio
Tipologia:
Versione Editoriale
Dimensione
2.23 MB
Formato
Adobe PDF
|
2.23 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.