The aim of this work is to establish inclusive guidelines on electroencephalography (EEG) applicable to all neonatal intensive care units (NICUs). Guidelines on ideal EEG monitoring for neonates are available, but there are significant barriers to their implementation in many centres around the world. These includebarriers due to limited resources regarding the availability of equipment and technical and interpretive round-the-clock personnel. On the other hand, despite its limitations, amplitude-integrated EEG (aEEG) (previously called Cerebral Function Monitor [CFM]) is a common alternative used in NICUs.The Italian Neonatal Seizure Collaborative Network (INNESCO), working with all national scientific societies interested in the field of neonatal clinical neurophysiology, performed a systematic literature review and promoted interdisciplinary discussions among experts (neonatologists, paediatric neurologists, neurophysiologists, technicians) between 2017 and 2020 with the aim of elaborating shared recommendations.A consensus statement on videoEEG (vEEG) and aEEG for the principal neonatal indications was established. The authors propose a flexible frame of recommendations based on the complementary use of vEEG and aEEG applicable to the various neonatal units with different levels of complexity according to local resources and specific patient features. Suggestions for promoting cooperation between neonatologists, paediatric neurologists, and neurophysiologists, organisational restructuring, and teleneurophysiology implementation are provided.(c) 2021 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

Dilena, O., Raviglione, F., Cantalupo, G., Cordelli, D.M., De Liso, P., Di Capua, M., et al. (2021). Consensus protocol for EEG and amplitude-integrated EEG assessment and monitoring in neonates [10.1016/j.clinph.2021.01.012].

Consensus protocol for EEG and amplitude-integrated EEG assessment and monitoring in neonates

Falsaperla, R;Piro, E
Membro del Collaboration Group
2021-01-01

Abstract

The aim of this work is to establish inclusive guidelines on electroencephalography (EEG) applicable to all neonatal intensive care units (NICUs). Guidelines on ideal EEG monitoring for neonates are available, but there are significant barriers to their implementation in many centres around the world. These includebarriers due to limited resources regarding the availability of equipment and technical and interpretive round-the-clock personnel. On the other hand, despite its limitations, amplitude-integrated EEG (aEEG) (previously called Cerebral Function Monitor [CFM]) is a common alternative used in NICUs.The Italian Neonatal Seizure Collaborative Network (INNESCO), working with all national scientific societies interested in the field of neonatal clinical neurophysiology, performed a systematic literature review and promoted interdisciplinary discussions among experts (neonatologists, paediatric neurologists, neurophysiologists, technicians) between 2017 and 2020 with the aim of elaborating shared recommendations.A consensus statement on videoEEG (vEEG) and aEEG for the principal neonatal indications was established. The authors propose a flexible frame of recommendations based on the complementary use of vEEG and aEEG applicable to the various neonatal units with different levels of complexity according to local resources and specific patient features. Suggestions for promoting cooperation between neonatologists, paediatric neurologists, and neurophysiologists, organisational restructuring, and teleneurophysiology implementation are provided.(c) 2021 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
2021
Dilena, O., Raviglione, F., Cantalupo, G., Cordelli, D.M., De Liso, P., Di Capua, M., et al. (2021). Consensus protocol for EEG and amplitude-integrated EEG assessment and monitoring in neonates [10.1016/j.clinph.2021.01.012].
File in questo prodotto:
File Dimensione Formato  
Consensus EEG Clinical neurophysiology 2021.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 1.53 MB
Formato Adobe PDF
1.53 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/582692
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 25
social impact