In this paper multilevel cascaded H-bridges (CHB) three phase inverters with 2n dc sources, n=1,2,3,... are considered and a mathematical formulation providing both 2n switching angles and dc voltage source to eliminate n+1 harmonics and their respective multiple from their output voltage waveform, is proposed. The computed angles don't depend on modulation index and the source voltages linearly vary with it. The proposed procedure finds the solution through an analytical formula that avoids to solve transcendental systems and presents very low computational cost. A lot of low order harmonics are eliminated, returning a very low total harmonic distortion (THD). Particularly for 9-level configuration, the first not mitigated harmonic is the 17th and the percentage THD is 5.59%.
Buccella C., Cimoroni M.G., Cecati C., Di Tommaso A.O., Nevoloso C., Schettino G. (2022). Mathematical formulation of pulse amplitude modulation selective harmonic elimination in multilevel three phase inverters. In 2022 International Symposium on Power Electronics, Electrical Drives, Automation and Motion, SPEEDAM 2022 (pp. 719-724). Institute of Electrical and Electronics Engineers Inc. [10.1109/SPEEDAM53979.2022.9841980].
Mathematical formulation of pulse amplitude modulation selective harmonic elimination in multilevel three phase inverters
Di Tommaso A. O.;Nevoloso C.;Schettino G.
2022-01-01
Abstract
In this paper multilevel cascaded H-bridges (CHB) three phase inverters with 2n dc sources, n=1,2,3,... are considered and a mathematical formulation providing both 2n switching angles and dc voltage source to eliminate n+1 harmonics and their respective multiple from their output voltage waveform, is proposed. The computed angles don't depend on modulation index and the source voltages linearly vary with it. The proposed procedure finds the solution through an analytical formula that avoids to solve transcendental systems and presents very low computational cost. A lot of low order harmonics are eliminated, returning a very low total harmonic distortion (THD). Particularly for 9-level configuration, the first not mitigated harmonic is the 17th and the percentage THD is 5.59%.File | Dimensione | Formato | |
---|---|---|---|
Mathematical_formulation_of_pulse_amplitude_modulation_selective_harmonic_elimination_in_multilevel_three_phase_inverters.pdf
Solo gestori archvio
Tipologia:
Versione Editoriale
Dimensione
808.59 kB
Formato
Adobe PDF
|
808.59 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.