Issues related to the stability of non-interconnected grids are of high relevance given the increasing presence of renewable sources in the power generation system. In order to ensure adequate levels of system's reliability, it is necessary to find new methods to ensure the stability of the electric grid. The present work proposes a methodology for the definition of the minimum number of Vehicle-to-Grid (V2G) charging points that would allow the integration of 1 MW of photovoltaic power in the power grid of the Italian island of Favignana, electrically disconnected from the continental grid. Primary frequency regulation simulations are carried out in Matlab/Simulink environment for different scenarios related to the generation park. The results show that with a limited number of V2G points levels of stability of the electrical system comparable to those before the installation of the photovoltaic plants can be ensured.
Ali Q., Di Silvestre M.L., Restifo G.L., Riva Sanseverino E., Sciume' G., Vasile A., et al. (2022). A Simulation Study for Assessing the Minimum Number of V2G Recharge Points in Favignana. In 2022 IEEE International Conference on Environment and Electrical Engineering and 2022 IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2022 (pp. 1-6). Institute of Electrical and Electronics Engineers Inc. [10.1109/EEEIC/ICPSEurope54979.2022.9854609].
A Simulation Study for Assessing the Minimum Number of V2G Recharge Points in Favignana
Ali Q.;Di Silvestre M. L.;Restifo G. L.;Riva Sanseverino E.;Sciume' G.;Vasile A.;Zizzo G.
2022-01-01
Abstract
Issues related to the stability of non-interconnected grids are of high relevance given the increasing presence of renewable sources in the power generation system. In order to ensure adequate levels of system's reliability, it is necessary to find new methods to ensure the stability of the electric grid. The present work proposes a methodology for the definition of the minimum number of Vehicle-to-Grid (V2G) charging points that would allow the integration of 1 MW of photovoltaic power in the power grid of the Italian island of Favignana, electrically disconnected from the continental grid. Primary frequency regulation simulations are carried out in Matlab/Simulink environment for different scenarios related to the generation park. The results show that with a limited number of V2G points levels of stability of the electrical system comparable to those before the installation of the photovoltaic plants can be ensured.File | Dimensione | Formato | |
---|---|---|---|
EEEIC04.pdf
Solo gestori archvio
Tipologia:
Versione Editoriale
Dimensione
680.52 kB
Formato
Adobe PDF
|
680.52 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.