Intense research activities have been carry out in the development of room temperature gamma ray spectroscopic imagers, aiming to compete with the excellent energy resolution of high-purity germanium (HPGe) detectors (0.3 % FWHM at 662 keV) obtained after cryogenic cooling. Cadmium-zinc-telluride (CZT) detectors equipped with pixel, strip and virtual Frisch-grid electrode structures represented an appealing solution for room temperature measurements. In this work, we present the performance of new high-resolution CZT drift strip detectors (19.4 x 19.4 x 6 mm3), recently fabricated at IMEM-CNR of Parma (Italy) in collaboration with due2lab company (Reggio Emilia, Italy). The detectors, working in planar transverse field (PTF) irradiation geometry, are able to perform 3D positioning and energy measurement of X rays and gamma rays: 2D positioning through cross-strip electrode patterns on the cathode/anode electrodes and the third coordinate by exploiting the C/A ratio and/or the drift time. A 32-channel digital electronics was used to process and analyze the zoo of collected/induced charge pulses from the strips. Excellent room temperature energy resolution (0.9 % FWHM at 662 keV) characterizes the detectors, after the application of a new correction technique. These activities follow the goals of two Italian research projects (3DCaTM and 3CaTS projects funded by ASI and INFN, respectively) on the development of spectroscopic X-ray and gamma ray imagers (10 keV-1 MeV) for medical and astrophysical applications.

Abbene L., Principato F., Gerardi G., Buttacavoli A., Altieri S., Gong C., et al. (2020). New Results on High-Resolution 3-D CZT Drift Strip Detectors. In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020 (pp. 1-3). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSS/MIC42677.2020.9507987].

New Results on High-Resolution 3-D CZT Drift Strip Detectors

Abbene L.
;
Principato F.;Buttacavoli A.;
2020-01-01

Abstract

Intense research activities have been carry out in the development of room temperature gamma ray spectroscopic imagers, aiming to compete with the excellent energy resolution of high-purity germanium (HPGe) detectors (0.3 % FWHM at 662 keV) obtained after cryogenic cooling. Cadmium-zinc-telluride (CZT) detectors equipped with pixel, strip and virtual Frisch-grid electrode structures represented an appealing solution for room temperature measurements. In this work, we present the performance of new high-resolution CZT drift strip detectors (19.4 x 19.4 x 6 mm3), recently fabricated at IMEM-CNR of Parma (Italy) in collaboration with due2lab company (Reggio Emilia, Italy). The detectors, working in planar transverse field (PTF) irradiation geometry, are able to perform 3D positioning and energy measurement of X rays and gamma rays: 2D positioning through cross-strip electrode patterns on the cathode/anode electrodes and the third coordinate by exploiting the C/A ratio and/or the drift time. A 32-channel digital electronics was used to process and analyze the zoo of collected/induced charge pulses from the strips. Excellent room temperature energy resolution (0.9 % FWHM at 662 keV) characterizes the detectors, after the application of a new correction technique. These activities follow the goals of two Italian research projects (3DCaTM and 3CaTS projects funded by ASI and INFN, respectively) on the development of spectroscopic X-ray and gamma ray imagers (10 keV-1 MeV) for medical and astrophysical applications.
2020
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Settore FIS/01 - Fisica Sperimentale
978-1-7281-7693-2
Abbene L., Principato F., Gerardi G., Buttacavoli A., Altieri S., Gong C., et al. (2020). New Results on High-Resolution 3-D CZT Drift Strip Detectors. In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020 (pp. 1-3). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSS/MIC42677.2020.9507987].
File in questo prodotto:
File Dimensione Formato  
L.Abbene_IEEEconferencerecord_2020.pdf

Solo gestori archvio

Descrizione: Contributo in atti di convegno pubblicato in volume
Tipologia: Post-print
Dimensione 622.54 kB
Formato Adobe PDF
622.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
CopyrightReceipt.pdf

Solo gestori archvio

Descrizione: Contributo in atti di convegno pubblicato in volume
Tipologia: Contratto con l'editore (ATTENZIONE: NON TRASFERIRE A SITO DOCENTE)
Dimensione 19.14 kB
Formato Adobe PDF
19.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Results from In Situ Monitoring of Radiation.pdf

Solo gestori archvio

Descrizione: Contributo in atti di convegno pubblicato in volume
Tipologia: Versione Editoriale
Dimensione 1.54 MB
Formato Adobe PDF
1.54 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/536660
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact