The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.

Caravello G., Cataliotti A., Di Cara D., Artale G., Cosentino V., Tine G., et al. (2021). Comparison of two different approaches for harmonic distortion sources assessment. In AMPS 2021 - 2021 11th IEEE International Workshop on Applied Measurements for Power Systems, Proceedings (pp. 1-6). Institute of Electrical and Electronics Engineers Inc. [10.1109/AMPS50177.2021.9586025].

Comparison of two different approaches for harmonic distortion sources assessment

Caravello G.;Cataliotti A.;Artale G.;Cosentino V.;Ditta V.;
2021-09-01

Abstract

The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.
set-2021
Settore ING-INF/07 - Misure Elettriche E Elettroniche
978-1-7281-6923-1
Caravello G., Cataliotti A., Di Cara D., Artale G., Cosentino V., Tine G., et al. (2021). Comparison of two different approaches for harmonic distortion sources assessment. In AMPS 2021 - 2021 11th IEEE International Workshop on Applied Measurements for Power Systems, Proceedings (pp. 1-6). Institute of Electrical and Electronics Engineers Inc. [10.1109/AMPS50177.2021.9586025].
File in questo prodotto:
File Dimensione Formato  
AMPS_2021_Comparison_of_two_different_approaches_for_harmonic_distortion_sources_assessment.pdf

Solo gestori archvio

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/527102
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact