This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this technique, a limit of detection <0.05 mM was found and the electrode shows high selectivity towards many chemicals. In order to very the possibility to recycle waste compact discs, the sensing platform was also obtained from burned compact discs and results shows a negligible interference from the burning process. The sensing platform has been used to quantify chloride ions in real samples showing high recovery rates.

Patella B., Aiello G., Torino C., Vilasi A., Oriordan A., Inguanta R. (2021). Silver based sensors from CD for chloride ions detection. In Silver based sensors from CD for chloride ions detection (pp. 1-4). Institute of Electrical and Electronics Engineers Inc. [10.1109/FLEPS51544.2021.9469858].

Silver based sensors from CD for chloride ions detection

Patella B.;Aiello G.;Inguanta R.
2021-09-09

Abstract

This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this technique, a limit of detection <0.05 mM was found and the electrode shows high selectivity towards many chemicals. In order to very the possibility to recycle waste compact discs, the sensing platform was also obtained from burned compact discs and results shows a negligible interference from the burning process. The sensing platform has been used to quantify chloride ions in real samples showing high recovery rates.
9-set-2021
Patella B., Aiello G., Torino C., Vilasi A., Oriordan A., Inguanta R. (2021). Silver based sensors from CD for chloride ions detection. In Silver based sensors from CD for chloride ions detection (pp. 1-4). Institute of Electrical and Electronics Engineers Inc. [10.1109/FLEPS51544.2021.9469858].
File in questo prodotto:
File Dimensione Formato  
Silver_based_sensors_from_CD_for_chloride_ions_detection.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 3.26 MB
Formato Adobe PDF
3.26 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/518293
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact