GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a fogging effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.

Calligaro C, Parlato A, Tomarchio E (2020). Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy. In 20th IEEE Mediterranean Electrotechnical Conference, MELECON 2020 - Proceedings (pp. 393-396). Institute of Electrical and Electronics Engineers Inc. [10.1109/MELECON48756.2020.9140609].

Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy

Parlato A
Data Curation
;
Tomarchio E
Conceptualization
2020-01-01

Abstract

GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a fogging effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.
2020
978-1-7281-5200-4
Calligaro C, Parlato A, Tomarchio E (2020). Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy. In 20th IEEE Mediterranean Electrotechnical Conference, MELECON 2020 - Proceedings (pp. 393-396). Institute of Electrical and Electronics Engineers Inc. [10.1109/MELECON48756.2020.9140609].
File in questo prodotto:
File Dimensione Formato  
09140609.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 885.3 kB
Formato Adobe PDF
885.3 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/509057
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact