This work is focused on the arc faults phenomenon in DC photovoltaic (PV) systems. The paper gives an overview of arc detection methods proposed in literature and presents a preliminary experimental characterization of the arcing current, focusing the attention on series arcs, whose detection is particularly challenging. Experimental tests are carried out, both in laboratory and on field, in order to investigate some relevant characteristics in the arcing current, which can be feasible for the arc detection purpose. Both arcing and non-arcing current signals are acquired and compared in both time and frequency domain. On-field measurements are carried out on a real photovoltaic system, in accordance with the tests requirements of UL 1699B Standard for protection devices against arc faults.
Artale G., Caravello G., Cataliotti A., Cosentino V., Cara D.D., Guaiana S., et al. (2020). DC series arc faults in PV systems. Detection methods and experimental characterization. In 24th IMEKO TC4 International Symposium and 22nd International Workshop on ADC and DAC Modelling and Testing (pp. 135-140). International Measurement Confederation (IMEKO).
DC series arc faults in PV systems. Detection methods and experimental characterization
Artale G.;Caravello G.;Cataliotti A.;Cosentino V.;Panzavecchia N.;
2020-01-01
Abstract
This work is focused on the arc faults phenomenon in DC photovoltaic (PV) systems. The paper gives an overview of arc detection methods proposed in literature and presents a preliminary experimental characterization of the arcing current, focusing the attention on series arcs, whose detection is particularly challenging. Experimental tests are carried out, both in laboratory and on field, in order to investigate some relevant characteristics in the arcing current, which can be feasible for the arc detection purpose. Both arcing and non-arcing current signals are acquired and compared in both time and frequency domain. On-field measurements are carried out on a real photovoltaic system, in accordance with the tests requirements of UL 1699B Standard for protection devices against arc faults.File | Dimensione | Formato | |
---|---|---|---|
IMEKO_TC-4_2020_Procs_paper.pdf
Solo gestori archvio
Descrizione: Articolo pubblicato
Tipologia:
Versione Editoriale
Dimensione
847.29 kB
Formato
Adobe PDF
|
847.29 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.