In this paper a new loss minimization control algorithm for inverter-fed permanent-magnet synchronous motors (PMSM), which allows to reduce the power losses of the electric drive without penalty on its dynamic performances, is analyzed, experimentally realized and validated. In particular, after a brief recall of two loss minimization control strategies (the "search control" and the "loss-model control"), both a modified dynamic model of the PMSM, which takes into account the iron losses, and a "loss-model" control strategy, are treated. Experimental tests on a specific PMSM drive employing the proposed loss minimization algorithm were performed aiming to validate the actual implementation. The main results of these tests confirm that the dynamic performances of the drive are maintained, and enhancement up to 3.5% of the efficiency can be reached in comparison to the PMSM drive equipped with a more traditional control strategy.
Cavallaro C., Di Tommaso A.O., Miceli R., Raciti A., Ricco Galluzzo G., Trapanese M. (2003). Analysis a DSP Implementation and Experimental Validation of a Loss Minimization Algorithm Applied to Permanent Magnet Synchronous Motor Drives. In IECON Proceedings (Industrial Electronics Conference) (pp. 312-317). 345 E 47TH ST, NEW YORK, NY 10017 USA : IEEE [10.1109/IECON.2003.1279998].
Analysis a DSP Implementation and Experimental Validation of a Loss Minimization Algorithm Applied to Permanent Magnet Synchronous Motor Drives
Di Tommaso A. O.;Miceli R.;Ricco Galluzzo G.;Trapanese M.
2003-01-01
Abstract
In this paper a new loss minimization control algorithm for inverter-fed permanent-magnet synchronous motors (PMSM), which allows to reduce the power losses of the electric drive without penalty on its dynamic performances, is analyzed, experimentally realized and validated. In particular, after a brief recall of two loss minimization control strategies (the "search control" and the "loss-model control"), both a modified dynamic model of the PMSM, which takes into account the iron losses, and a "loss-model" control strategy, are treated. Experimental tests on a specific PMSM drive employing the proposed loss minimization algorithm were performed aiming to validate the actual implementation. The main results of these tests confirm that the dynamic performances of the drive are maintained, and enhancement up to 3.5% of the efficiency can be reached in comparison to the PMSM drive equipped with a more traditional control strategy.File | Dimensione | Formato | |
---|---|---|---|
REVISED_IECON_finale2.pdf
accesso aperto
Tipologia:
Pre-print
Dimensione
547.33 kB
Formato
Adobe PDF
|
547.33 kB | Adobe PDF | Visualizza/Apri |
01279998.pdf
Solo gestori archvio
Tipologia:
Versione Editoriale
Dimensione
418.94 kB
Formato
Adobe PDF
|
418.94 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.