Integrity of industrial pipework is ensured through routine inspection. Internal visual inspection tools are capable of characterising degradation in the form of corrosion, pitting, erosion and cracking. The accuracy of such inspection systems has a direct impact on decisions regarding the remaining lifetime of the asset. By minimising error margins, the asset may be operated with confidence for longer, with less uncertainty. This paper considers a probe system consisting of a laser profiler and camera that produces a textured 3D model of the internals of 2 - 6 inch pipework. The accuracy of the system is defined by the ability to extract laser projections from an image as it travels down the pipe, to accurately reconstruct these projections into 3D and to estimate the probe trajectory as it travels through the pipe. This paper presents an error model of the laser profiler. It then presents a novel calibration routine to reduce the error caused by misalignment and tolerances during fabrication of the system. A key advantage of the proposed calibration technique over alternatives is that we can calibrate for errors without manually adjusting the probe, which enables fabrication of a smaller more robust measurement system. In lab-based trials our calibration technique reduced peak sizing errors from 2.7 mm to 0.14 mm in 120 mm diameter pipes.

Jackson W., Dobie G., MacLeod C., West G., Mineo C., McDonald L. (2020). Error Analysis and Calibration for a Novel Pipe Profiling Tool. IEEE SENSORS JOURNAL, 20(7), 3545-3555 [10.1109/JSEN.2019.2960939].

Error Analysis and Calibration for a Novel Pipe Profiling Tool

Mineo C.;
2020-01-01

Abstract

Integrity of industrial pipework is ensured through routine inspection. Internal visual inspection tools are capable of characterising degradation in the form of corrosion, pitting, erosion and cracking. The accuracy of such inspection systems has a direct impact on decisions regarding the remaining lifetime of the asset. By minimising error margins, the asset may be operated with confidence for longer, with less uncertainty. This paper considers a probe system consisting of a laser profiler and camera that produces a textured 3D model of the internals of 2 - 6 inch pipework. The accuracy of the system is defined by the ability to extract laser projections from an image as it travels down the pipe, to accurately reconstruct these projections into 3D and to estimate the probe trajectory as it travels through the pipe. This paper presents an error model of the laser profiler. It then presents a novel calibration routine to reduce the error caused by misalignment and tolerances during fabrication of the system. A key advantage of the proposed calibration technique over alternatives is that we can calibrate for errors without manually adjusting the probe, which enables fabrication of a smaller more robust measurement system. In lab-based trials our calibration technique reduced peak sizing errors from 2.7 mm to 0.14 mm in 120 mm diameter pipes.
2020
Jackson W., Dobie G., MacLeod C., West G., Mineo C., McDonald L. (2020). Error Analysis and Calibration for a Novel Pipe Profiling Tool. IEEE SENSORS JOURNAL, 20(7), 3545-3555 [10.1109/JSEN.2019.2960939].
File in questo prodotto:
File Dimensione Formato  
08936951.pdf

Solo gestori archvio

Descrizione: Articolo completo
Tipologia: Versione Editoriale
Dimensione 9.35 MB
Formato Adobe PDF
9.35 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Jackson_etal_Sensors_2020_Error_analysis_and_calibration_for_a_novel_pipe_profiling_tool.pdf

accesso aperto

Tipologia: Post-print
Dimensione 16.59 MB
Formato Adobe PDF
16.59 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/425294
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact