The public consciousness of the seismic risk is continuously increasing, although the damage on existing and older buildings due to earthquakes is still high, due to a former structural design not accounting for the latest knowledge achieved in the seismic field. This is particularly true considering the damage recorded in the last earthquakes that hit Central Italy in August and October 2016. The paper deals with the repair actions required in the elementary school of Pievebovigliana (Macerata-Italy) after the aforementioned seismic events. The school is a one-story building characterized by an irregular plan layout; masonry walls with regular blocks are the main supporting structure. An attempt is made to adopt a Life Cycle Thinking approach in the design of the intervention. The energy efficiency and environmental impacts related to different types of retrofit intervention are assessed. The retrofit interventions are conceived as carried out from the outside and using prefabricated solutions to minimize the building downtime and to facilitate the construction sequence. The structural retrofit is designed to reduce the damage to the existing masonry walls in the case of seismic events.

LABO’, S., BELLERI, A., PASSONI, C., MARINI, A., LONGO, S., CELLURA, M. (2018). Design of the seismic retrofit of a school in accordance to a life cycle thinking approach. In Proceedings of the 16th European Conference on Earthquake Engineering.

Design of the seismic retrofit of a school in accordance to a life cycle thinking approach

LONGO, Sonia;CELLURA, Maurizio
2018-01-01

Abstract

The public consciousness of the seismic risk is continuously increasing, although the damage on existing and older buildings due to earthquakes is still high, due to a former structural design not accounting for the latest knowledge achieved in the seismic field. This is particularly true considering the damage recorded in the last earthquakes that hit Central Italy in August and October 2016. The paper deals with the repair actions required in the elementary school of Pievebovigliana (Macerata-Italy) after the aforementioned seismic events. The school is a one-story building characterized by an irregular plan layout; masonry walls with regular blocks are the main supporting structure. An attempt is made to adopt a Life Cycle Thinking approach in the design of the intervention. The energy efficiency and environmental impacts related to different types of retrofit intervention are assessed. The retrofit interventions are conceived as carried out from the outside and using prefabricated solutions to minimize the building downtime and to facilitate the construction sequence. The structural retrofit is designed to reduce the damage to the existing masonry walls in the case of seismic events.
2018
Settore ING-IND/11 - Fisica Tecnica Ambientale
LABO’, S., BELLERI, A., PASSONI, C., MARINI, A., LONGO, S., CELLURA, M. (2018). Design of the seismic retrofit of a school in accordance to a life cycle thinking approach. In Proceedings of the 16th European Conference on Earthquake Engineering.
File in questo prodotto:
File Dimensione Formato  
12112 - Labo et al_.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 3.7 MB
Formato Adobe PDF
3.7 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/291512
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact