Rich literature explores materials and construction techniques of historic buildings, but limited information is available about the thermal and hygrometric features of their envelope. Nevertheless, accurate hygrothermal data are essential for identifying effective energy upgrade measures, which must be compatible with the conservation of the architectural heritage. In order to fill this gap, it is necessary to refer to local contexts, where the variety of historic buildings is limited and their material and construction features are comparable.
L'articolo descrive i risultati di una campagna di venti misure in opera di conduttanza termica (ISO 9869), svolta nell'arco di due anni sulle murature storiche del complesso monumentale di Sant'Anna la Misericordia a Palermo. Scopo dello studio è contribuire allo sviluppo di un quadro generale di conoscenze sulle caratteristiche termiche e igrometriche della costruzione storica siciliana. I risultati delle misure in opera sono confrontati con valori di calcolo (UNI EN ISO 6946), basati su dati desunti dalle norme tecniche UNI 10351, UNI EN ISO 10456, UNI EN 1745 e dal rapporto tecnico UNI/TR 11552. Per le murature indagate, i risultati di calcolo si mostrano corrispondenti a quelli di misura se si adoperano i dati di conduttività termica che la norma UNI 10351 attribuisce ai "tufi"; i calcoli fondati sui dati riportati dalla UNI EN ISO 10456 per le rocce sedimentarie leggere tendono invece a sovrastimare la conduttanza termica delle murature in conci di calcarenite.
Genova, E., Fatta, G. (2018). The thermal performances of historic masonry: In-situ measurements of thermal conductance on calcarenite stone walls in Palermo. ENERGY AND BUILDINGS, 168, 363-373 [10.1016/j.enbuild.2018.03.009].
The thermal performances of historic masonry: In-situ measurements of thermal conductance on calcarenite stone walls in Palermo
Genova, Enrico
;Fatta, Giovanni
2018-01-01
Abstract
Rich literature explores materials and construction techniques of historic buildings, but limited information is available about the thermal and hygrometric features of their envelope. Nevertheless, accurate hygrothermal data are essential for identifying effective energy upgrade measures, which must be compatible with the conservation of the architectural heritage. In order to fill this gap, it is necessary to refer to local contexts, where the variety of historic buildings is limited and their material and construction features are comparable.File | Dimensione | Formato | |
---|---|---|---|
energy and buildings.pdf
Solo gestori archvio
Descrizione: articolo principale
Dimensione
1.89 MB
Formato
Adobe PDF
|
1.89 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.