In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm2) and a central anode (2 x 2 mm2) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm2at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWHM at 59.5 keV (241Am source) up to 2200 V, by using a commercial front-end electronics (A250F/NF charge sensitive preamplifier, Amptek, USA; nominal equivalent noise charge ENC of 100 electrons RMS). At high rates (1 Mcps), the detectors, coupled to a custom-designed digital pulse processing electronics developed at DiFC of University of Palermo (Italy), show low spectroscopic degradations: energy resolution values of 8 % and 9.7 % FWHM at 59.5 keV (241Am source) were measured, with throughputs of 0.4 % and 60 %, respectively. These activities are in the framework of an Italian research project on the development of energy-resolved photon counting (ERPC) systems for high flux energy-resolved X-ray imaging.

Abbene, L., Zambelli, N., Gerardi, G., Raso, G., Benassi, G., Bettelli, M., et al. (2017). High bias voltage CZT detectors for high-flux measurements. In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 (pp. 1-6). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2016.8069962].

High bias voltage CZT detectors for high-flux measurements

Abbene, L.
;
Gerardi, G.;Raso, G.;Principato, F.;
2017-10-16

Abstract

In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm2) and a central anode (2 x 2 mm2) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm2at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWHM at 59.5 keV (241Am source) up to 2200 V, by using a commercial front-end electronics (A250F/NF charge sensitive preamplifier, Amptek, USA; nominal equivalent noise charge ENC of 100 electrons RMS). At high rates (1 Mcps), the detectors, coupled to a custom-designed digital pulse processing electronics developed at DiFC of University of Palermo (Italy), show low spectroscopic degradations: energy resolution values of 8 % and 9.7 % FWHM at 59.5 keV (241Am source) were measured, with throughputs of 0.4 % and 60 %, respectively. These activities are in the framework of an Italian research project on the development of energy-resolved photon counting (ERPC) systems for high flux energy-resolved X-ray imaging.
16-ott-2017
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Settore FIS/01 - Fisica Sperimentale
9781509016426
Abbene, L., Zambelli, N., Gerardi, G., Raso, G., Benassi, G., Bettelli, M., et al. (2017). High bias voltage CZT detectors for high-flux measurements. In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 (pp. 1-6). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2016.8069962].
File in questo prodotto:
File Dimensione Formato  
L.Abbene_RTSD_CZT_high_bias_detetctors_2017.pdf

Solo gestori archvio

Descrizione: articolo
Tipologia: Versione Editoriale
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/271789
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact