High levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This study aims at evaluating the equivalent and peak noise levels inside a modern oil mill plant area in Sicily, south Italy. Twenty measurement points were identified inside the oil mill plant area where the machines for olive oil extraction were located (about 200 m2). The instrument used for the measurements was a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. The measured sound levels exceeded the limits allowed by the regulations in all the measurement points inside the working area; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 93.3 dB(A) close to the hammer crusher. The operators involved are consequently obliged to wear the appropriate Personal Protective Equipment.
Vallone, M., Morello, G., Catania, P. (2017). Noise risk assessment in a modern olive oil mill. CHEMICAL ENGINEERING TRANSACTIONS, 58, 139-144 [10.3303/CET1758024].
Noise risk assessment in a modern olive oil mill
VALLONE, Mariangela
Investigation
;MORELLO, GiuseppeMembro del Collaboration Group
;CATANIA, PietroConceptualization
2017-01-01
Abstract
High levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This study aims at evaluating the equivalent and peak noise levels inside a modern oil mill plant area in Sicily, south Italy. Twenty measurement points were identified inside the oil mill plant area where the machines for olive oil extraction were located (about 200 m2). The instrument used for the measurements was a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. The measured sound levels exceeded the limits allowed by the regulations in all the measurement points inside the working area; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 93.3 dB(A) close to the hammer crusher. The operators involved are consequently obliged to wear the appropriate Personal Protective Equipment.File | Dimensione | Formato | |
---|---|---|---|
024_Noise Risk Assessment in a Modern Olive Oil Mill.pdf
accesso aperto
Descrizione: articolo principale
Dimensione
720.97 kB
Formato
Adobe PDF
|
720.97 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.