In the research field of emergency dosimeters to be used in case of accidental radiation exposure of the population, watch glass has been considered as a possible fortuitous dosimetric material. This paper reports on results obtained by thermoluminescence of glass samples exposed to neutron and proton beams. Thermoluminescent glow curves have been analyzed for each irradiation studying the modifications induced by the irradiation as a function of proton dose or neutron fluence. The glow curve in a specific temperature range has been used as dosimetric parameter. The thermoluminescence response of samples exposed to protons has been found to be linear in the dose range between 2 and 20 Gy and the lowest detectable dose for this radiation beam is estimated to be smaller than than 1 Gy. In case of exposure with thermal neutrons the TL signal linearly increases with neutron fluence (up to about 3 × 1011 cm-2) and the lowest detectable fluence has been found to be of the order of magnitude of 109 cm-2. These results could be of interest for accidental retrospective dosimetry. © 2012 Elsevier B.V. All rights reserved.

Marrale, M., Longo, A., Bartolotta, A., Basile, S., D'Oca, M., Tomarchio, E., et al. (2012). Thermoluminescence response of sodalime glass irradiated with proton and neutron beams. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 292, 55-58 [10.1016/j.nimb.2012.10.003].

Thermoluminescence response of sodalime glass irradiated with proton and neutron beams

MARRALE, Maurizio;LONGO, Anna;BARTOLOTTA, Antonio;BASILE, Salvatore;D'OCA, Maria Cristina;TOMARCHIO, Elio Angelo;
2012-01-01

Abstract

In the research field of emergency dosimeters to be used in case of accidental radiation exposure of the population, watch glass has been considered as a possible fortuitous dosimetric material. This paper reports on results obtained by thermoluminescence of glass samples exposed to neutron and proton beams. Thermoluminescent glow curves have been analyzed for each irradiation studying the modifications induced by the irradiation as a function of proton dose or neutron fluence. The glow curve in a specific temperature range has been used as dosimetric parameter. The thermoluminescence response of samples exposed to protons has been found to be linear in the dose range between 2 and 20 Gy and the lowest detectable dose for this radiation beam is estimated to be smaller than than 1 Gy. In case of exposure with thermal neutrons the TL signal linearly increases with neutron fluence (up to about 3 × 1011 cm-2) and the lowest detectable fluence has been found to be of the order of magnitude of 109 cm-2. These results could be of interest for accidental retrospective dosimetry. © 2012 Elsevier B.V. All rights reserved.
2012
Marrale, M., Longo, A., Bartolotta, A., Basile, S., D'Oca, M., Tomarchio, E., et al. (2012). Thermoluminescence response of sodalime glass irradiated with proton and neutron beams. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 292, 55-58 [10.1016/j.nimb.2012.10.003].
File in questo prodotto:
File Dimensione Formato  
NIM 2012.pdf

Solo gestori archvio

Dimensione 288.96 kB
Formato Adobe PDF
288.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/212664
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact