Today, the measurement of the polarization status of cosmic sources high-energy emission, is recognized as a key observational parameter to understand the active production mechanism and its geometry. Therefore, a mandatory requirement for new instrumentations operating in this energy range will be to provide high sensitivity for polarimetric measurements. In this framework, we have presented the concept of a small high-performance imaging spectrometer optimized for polarimetry between 100 and 600 keV suitable for a stratospheric balloon-borne payload and as a pathfinder for a future satellite mission. The detector with 3D spatial resolution is based on a CZT spectrometer in a highly segmented configuration designed to operate simultaneously as a high performance scattering polarimeter. Herein, we report results of a Monte Carlo study devoted to optimize the configuration of the detector for polarimetry with particular focus on event selection filter able to increase the polarimetric performance. This preliminary analysis shows that a procedure to optimize the polarization response of a 3D spectrometers should first of all determine the best tradeoff between the statistical significance and the quality of the modulation factor.
Caroli, E., De Cesare, G., Da Silva, R., Abbene, L., Auricchio, N., Budtz-Jorgensen, C., et al. (2016). Monte Carlo evaluation of a CZT 3D spectrometer suitable for a Hard X- and soft-γ rays polarimetry balloon borne experiment. In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015 (pp. 1-5). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2015.7582278].
Monte Carlo evaluation of a CZT 3D spectrometer suitable for a Hard X- and soft-γ rays polarimetry balloon borne experiment
ABBENE, Leonardo;
2016-10-03
Abstract
Today, the measurement of the polarization status of cosmic sources high-energy emission, is recognized as a key observational parameter to understand the active production mechanism and its geometry. Therefore, a mandatory requirement for new instrumentations operating in this energy range will be to provide high sensitivity for polarimetric measurements. In this framework, we have presented the concept of a small high-performance imaging spectrometer optimized for polarimetry between 100 and 600 keV suitable for a stratospheric balloon-borne payload and as a pathfinder for a future satellite mission. The detector with 3D spatial resolution is based on a CZT spectrometer in a highly segmented configuration designed to operate simultaneously as a high performance scattering polarimeter. Herein, we report results of a Monte Carlo study devoted to optimize the configuration of the detector for polarimetry with particular focus on event selection filter able to increase the polarimetric performance. This preliminary analysis shows that a procedure to optimize the polarization response of a 3D spectrometers should first of all determine the best tradeoff between the statistical significance and the quality of the modulation factor.File | Dimensione | Formato | |
---|---|---|---|
Caroli_RTSD_2015.pdf
Solo gestori archvio
Descrizione: articolo
Tipologia:
Versione Editoriale
Dimensione
479.38 kB
Formato
Adobe PDF
|
479.38 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.