Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. This tecnique allows to deliver high doses of radiation to the tumor sparing the surrounding healthy tissue. In this study the accuracy of the dose delivered in a SRS session by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test. This is perfome d by means of alanine Electron Paramagnetic Resonance (EPR) pe llets. The response of these dosimeters is compared to that of gafchromic films which are particularly suitable for two-dimensional dose verification providing accurate estimate of the distribution and of the gradients of the absorbed dose.

S, P., G, I., M, M., S, G., A, L., T, C., et al. (2016). Dose verification with EPR/alanine dosimeters in Helical Tomotherapy Stereotactic Radiosurgery (HT SRS) treatments. In Abstract of 18th International Conference on Solid State Dosimetry.

Dose verification with EPR/alanine dosimeters in Helical Tomotherapy Stereotactic Radiosurgery (HT SRS) treatments

PANZECA, Salvatore;MARRALE, Maurizio;GALLO, Salvatore;LONGO, Anna;BRAI, Maria
2016-01-01

Abstract

Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. This tecnique allows to deliver high doses of radiation to the tumor sparing the surrounding healthy tissue. In this study the accuracy of the dose delivered in a SRS session by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test. This is perfome d by means of alanine Electron Paramagnetic Resonance (EPR) pe llets. The response of these dosimeters is compared to that of gafchromic films which are particularly suitable for two-dimensional dose verification providing accurate estimate of the distribution and of the gradients of the absorbed dose.
2016
ESR, EPR, Dosimetry, Helical Tomotherapy,Stereotactic Radiosurgery treatments
S, P., G, I., M, M., S, G., A, L., T, C., et al. (2016). Dose verification with EPR/alanine dosimeters in Helical Tomotherapy Stereotactic Radiosurgery (HT SRS) treatments. In Abstract of 18th International Conference on Solid State Dosimetry.
File in questo prodotto:
File Dimensione Formato  
SSD_TOMO.pdf

Solo gestori archvio

Descrizione: Abstract Atti congresso
Dimensione 764.6 kB
Formato Adobe PDF
764.6 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/180441
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact