This paper presents an investigation and a comprehensive analysis on fault operations in a conventional three-phase voltage source inverter. After an introductory section dealing with power converter reliability and fault analysis issues in power electronics, a generalized switching function accounting for both healthy and faulty conditions and an easy and feasible method to embed fault diagnosis and reconfiguration within the control algorithm are introduced. The proposed system has simple and compact implementation. Experimental results operating both at open- and closed-loop current control, obtained using a test bench realized using a dSPACE system and the fault-tolerant inverter prototype demonstrate that the proposed solution is effective and feasible and makes all faults easily managed by the controller itself.
Cecati, C., Di Tommaso, A.O., Genduso, F., Miceli, R., Ricco Galluzzo, G. (2015). Comprehensive Modeling and Experimental Testing of Fault Detection and Management of a Nonredundant Fault-Tolerant VSI. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 62(6), 3945-3954 [10.1109/TIE.2015.2402645].
Comprehensive Modeling and Experimental Testing of Fault Detection and Management of a Nonredundant Fault-Tolerant VSI
DI TOMMASO, Antonino Oscar;GENDUSO, Fabio;MICELI, Rosario;RICCO GALLUZZO, Giuseppe
2015-01-01
Abstract
This paper presents an investigation and a comprehensive analysis on fault operations in a conventional three-phase voltage source inverter. After an introductory section dealing with power converter reliability and fault analysis issues in power electronics, a generalized switching function accounting for both healthy and faulty conditions and an easy and feasible method to embed fault diagnosis and reconfiguration within the control algorithm are introduced. The proposed system has simple and compact implementation. Experimental results operating both at open- and closed-loop current control, obtained using a test bench realized using a dSPACE system and the fault-tolerant inverter prototype demonstrate that the proposed solution is effective and feasible and makes all faults easily managed by the controller itself.File | Dimensione | Formato | |
---|---|---|---|
07039264.pdf
Solo gestori archvio
Descrizione: Articolo completo
Tipologia:
Versione Editoriale
Dimensione
2.29 MB
Formato
Adobe PDF
|
2.29 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
tieft2013-cecati-NOV27-1.pdf
accesso aperto
Tipologia:
Post-print
Dimensione
3.12 MB
Formato
Adobe PDF
|
3.12 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.