The present paper focuses on an in-situ testing campaign recently developed in the Messina area, Italy, aiming at the assessment of the in-plane shear behaviour of traditional masonry retrofitted with the innovative CAM system (a system of 3D pre-tensioned stainless steel ties). The typical masonry of Messina area, is characterised by low mechanical properties, both for its texture and for the bad quality of mortar, as well as lack of transverse connections. The high seismic risk characterizing the zone, amplifies the need for in-plane strengthening and transverse connections improving. The CAM system, Masonry Active Ties or Manufact Active Confining, allows to realise a 3D pre-tensioned tying system which is able to compact stones and mortar and improve the masonry mechanical characteristics. Seven full scale panels were cut from an ancient walls in-situ for shearcompression tests. A panel was used to evaluate the mechanical characteristics in compression of masonry, the others were reinforced using a polymeric net immersed in the external plaster and varying the setup and the mechanical characteristics of CAM system. Ultimate capacity and ductility increment, as well as modification of the original failure mode, resulted from the CAM retrofitting system under shear compressive tests.

Cilia, M., Colajanni, P., Marnetto, R., Recupero, A., Spinella N. (2014). Experimental Tests on Typical Masonry of Messina Area (Italy) Retrofitted with CAM: Full Scale Panels. In Proocedings of 9th International Masonry Conference.

Experimental Tests on Typical Masonry of Messina Area (Italy) Retrofitted with CAM: Full Scale Panels

COLAJANNI, Piero;
2014-01-01

Abstract

The present paper focuses on an in-situ testing campaign recently developed in the Messina area, Italy, aiming at the assessment of the in-plane shear behaviour of traditional masonry retrofitted with the innovative CAM system (a system of 3D pre-tensioned stainless steel ties). The typical masonry of Messina area, is characterised by low mechanical properties, both for its texture and for the bad quality of mortar, as well as lack of transverse connections. The high seismic risk characterizing the zone, amplifies the need for in-plane strengthening and transverse connections improving. The CAM system, Masonry Active Ties or Manufact Active Confining, allows to realise a 3D pre-tensioned tying system which is able to compact stones and mortar and improve the masonry mechanical characteristics. Seven full scale panels were cut from an ancient walls in-situ for shearcompression tests. A panel was used to evaluate the mechanical characteristics in compression of masonry, the others were reinforced using a polymeric net immersed in the external plaster and varying the setup and the mechanical characteristics of CAM system. Ultimate capacity and ductility increment, as well as modification of the original failure mode, resulted from the CAM retrofitting system under shear compressive tests.
Settore ICAR/09 - Tecnica Delle Costruzioni
lug-2014
9th International Masonry Conference, 9IMC2014
Guimarães, Portugal
7-9 July 2014
9
2014
12
Cilia, M., Colajanni, P., Marnetto, R., Recupero, A., Spinella N. (2014). Experimental Tests on Typical Masonry of Messina Area (Italy) Retrofitted with CAM: Full Scale Panels. In Proocedings of 9th International Masonry Conference.
Proceedings (atti dei congressi)
Cilia, M; Colajanni, P; Marnetto, R. ; Recupero, A; Spinella N.
File in questo prodotto:
File Dimensione Formato  
2014_IMS_Guimaraes_Panels.pdf

Solo gestori archvio

Descrizione: Articolo principale
Dimensione 2.72 MB
Formato Adobe PDF
2.72 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/101294
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact