This paper is focused on the use of data acquisition boards (DAQs) for the development of high accuracy PC-based instruments for the measurements of electrical power. The proposed systems are simple, portable and low cost because they are based on commercial data acquisition boards (DAQs) connected to a common personal computer. Data processing is carried out by a commercial software based on an interpolating windowed FFT. In the paper it is shown how the voltage can be sensed directly, thanks to the DAQ input range, thus avoiding expensive voltage dividers. The set up of the DAQs-based solutions is described and the evaluation of their metrological features is made by means of a comparison with the Italian power primary standard, which was built at INRIM with a complex solution and expensive with two high precision digital voltmeters.

Cataliotti, A., Cosentino, V., Lipari, A., Nuccio, S., Serazio, D. (2013). DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard. MEASUREMENT, Vol 46, N. 9(Vol 46, No 9), 3460-3468 [10.1016/j.measurement.2013.05.031].

DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard

CATALIOTTI, Antonio;COSENTINO, Valentina;LIPARI, Alessandro;NUCCIO, Salvatore;
2013-01-01

Abstract

This paper is focused on the use of data acquisition boards (DAQs) for the development of high accuracy PC-based instruments for the measurements of electrical power. The proposed systems are simple, portable and low cost because they are based on commercial data acquisition boards (DAQs) connected to a common personal computer. Data processing is carried out by a commercial software based on an interpolating windowed FFT. In the paper it is shown how the voltage can be sensed directly, thanks to the DAQ input range, thus avoiding expensive voltage dividers. The set up of the DAQs-based solutions is described and the evaluation of their metrological features is made by means of a comparison with the Italian power primary standard, which was built at INRIM with a complex solution and expensive with two high precision digital voltmeters.
2013
Cataliotti, A., Cosentino, V., Lipari, A., Nuccio, S., Serazio, D. (2013). DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard. MEASUREMENT, Vol 46, N. 9(Vol 46, No 9), 3460-3468 [10.1016/j.measurement.2013.05.031].
File in questo prodotto:
File Dimensione Formato  
MEASUREMENT_DAQs-based wattmeter.pdf

Solo gestori archvio

Dimensione 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/83844
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact