Background/Objectives: Tapered, fluted, modular titanium stems (TFTSs) are widely used in complex femoral reconstructions during total hip arthroplasty (THA), but evidence regarding the clinical performance of specific modular implant designs remains limited. This study aimed to compare the early clinical and radiographic outcomes of complex primary and revision THA using the M-Vizion® modular stem system. Methods: We retrospectively analyzed 109 patients (46 complex primary and 63 revision THA cases) treated with the M-Vizion® cementless modular TFTSs between 2020 and 2023. Clinical outcomes were assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS) and the Forgotten Joint Score (FJS) at 1-and 2-years post-surgery. Radiographic evaluation included stem subsidence, radiolucent lines, heterotopic ossification, and complications. Clinically relevant subsidence was defined as >5 mm. Statistical analysis was performed using ANOVA. Results: The mean follow-up was 33.3 months for complex primary and 31.8 months for revision THA. Both groups demonstrated significant improvement in FJS over time (p < 0.05). In the revision group, HOOS improved significantly from baseline to follow-up (p < 0.001). Mean stem subsidence was 2.1 mm in the complex primary group and 1.8 mm in the revision group; nine patients (8.3%) had subsidence greater than 5 mm. No cases of aseptic loosening or stem fracture were observed. The overall complication rate was low, with dislocations (3.2%) and infections (2.8%) requiring revision. Conclusions: The M-Vizion® TFTS system demonstrated favorable short-term outcomes in both complex primary and revision THA. These findings suggest potential utility in complex femoral reconstruction, although confirmation through longer-term studies is warranted.
Meo, F.D., Cacciola, G., Bosco, F., Bruschetta, A., Cavaliere, P. (2025). Comparison of Early Clinical and Radiographic Outcomes of Complex Primary and Revision Total Hip Arthroplasty Using a Tapered, Fluted, Modular Titanium Stem System. PROSTHESIS, 7(5) [10.3390/PROSTHESIS7050104].
Comparison of Early Clinical and Radiographic Outcomes of Complex Primary and Revision Total Hip Arthroplasty Using a Tapered, Fluted, Modular Titanium Stem System
Bosco F.;
2025-08-22
Abstract
Background/Objectives: Tapered, fluted, modular titanium stems (TFTSs) are widely used in complex femoral reconstructions during total hip arthroplasty (THA), but evidence regarding the clinical performance of specific modular implant designs remains limited. This study aimed to compare the early clinical and radiographic outcomes of complex primary and revision THA using the M-Vizion® modular stem system. Methods: We retrospectively analyzed 109 patients (46 complex primary and 63 revision THA cases) treated with the M-Vizion® cementless modular TFTSs between 2020 and 2023. Clinical outcomes were assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS) and the Forgotten Joint Score (FJS) at 1-and 2-years post-surgery. Radiographic evaluation included stem subsidence, radiolucent lines, heterotopic ossification, and complications. Clinically relevant subsidence was defined as >5 mm. Statistical analysis was performed using ANOVA. Results: The mean follow-up was 33.3 months for complex primary and 31.8 months for revision THA. Both groups demonstrated significant improvement in FJS over time (p < 0.05). In the revision group, HOOS improved significantly from baseline to follow-up (p < 0.001). Mean stem subsidence was 2.1 mm in the complex primary group and 1.8 mm in the revision group; nine patients (8.3%) had subsidence greater than 5 mm. No cases of aseptic loosening or stem fracture were observed. The overall complication rate was low, with dislocations (3.2%) and infections (2.8%) requiring revision. Conclusions: The M-Vizion® TFTS system demonstrated favorable short-term outcomes in both complex primary and revision THA. These findings suggest potential utility in complex femoral reconstruction, although confirmation through longer-term studies is warranted.| File | Dimensione | Formato | |
|---|---|---|---|
|
prosthesis-07-00104-v2.pdf
accesso aperto
Descrizione: Comparison of Early Clinical and Radiographic Outcomes of Complex Primary and Revision Total Hip Arthroplasty Using a Tapered, Fluted, Modular Titanium Stem System
Tipologia:
Versione Editoriale
Dimensione
874.74 kB
Formato
Adobe PDF
|
874.74 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


