Ionoacoustic tomography exploits the acoustic signal generated by the fast energy deposition along the path of pulsed particle beams to reconstruct with sub-mm precision the dose deposition, with promising envisioned applications in hadron therapy treatment monitoring. State-of-the-art ionoacoustic detectors mainly rely on single-channel sensors and time-of-flight measurements to provide 1D localization of the maximum dose deposition at the so-called Bragg peak. This work investigates the design challenges of multichannel sensors for ionoacoustic tomography in terms of their ability to accurately reconstruct the dose deposition of a 200 MeV clinical proton beam, highlighting the impact of the number of channels in the array and their directivity. A complete acoustic model of the sensors and environment has been developed and used to find an optimum tradeoff between accuracy, evaluated numerically through the gamma index, and hardware complexity due to higher channel numbers, thus minimizing the system-level power consumption of the detector.

Vallicelli, E.A., Ferrara, A.M., Marrale, M., Tambaro, M., De Matteis, M. (2024). Multichannel Sensor Array Design for Minimizing Detector Complexity and Power Consumption in Ionoacoustic Proton Beam Tomography. JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS, 14(4) [10.3390/jlpea14040051].

Multichannel Sensor Array Design for Minimizing Detector Complexity and Power Consumption in Ionoacoustic Proton Beam Tomography

Marrale M.;
2024-10-30

Abstract

Ionoacoustic tomography exploits the acoustic signal generated by the fast energy deposition along the path of pulsed particle beams to reconstruct with sub-mm precision the dose deposition, with promising envisioned applications in hadron therapy treatment monitoring. State-of-the-art ionoacoustic detectors mainly rely on single-channel sensors and time-of-flight measurements to provide 1D localization of the maximum dose deposition at the so-called Bragg peak. This work investigates the design challenges of multichannel sensors for ionoacoustic tomography in terms of their ability to accurately reconstruct the dose deposition of a 200 MeV clinical proton beam, highlighting the impact of the number of channels in the array and their directivity. A complete acoustic model of the sensors and environment has been developed and used to find an optimum tradeoff between accuracy, evaluated numerically through the gamma index, and hardware complexity due to higher channel numbers, thus minimizing the system-level power consumption of the detector.
30-ott-2024
Settore PHYS-06/A - Fisica per le scienze della vita, l'ambiente e i beni culturali
Vallicelli, E.A., Ferrara, A.M., Marrale, M., Tambaro, M., De Matteis, M. (2024). Multichannel Sensor Array Design for Minimizing Detector Complexity and Power Consumption in Ionoacoustic Proton Beam Tomography. JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS, 14(4) [10.3390/jlpea14040051].
File in questo prodotto:
File Dimensione Formato  
2024_AA100_Multichannel_Sensor_Array.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 3.51 MB
Formato Adobe PDF
3.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/706944
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact