Corrosion behaviour of commercially pure Zn during immersion up to 4 weeks is studied in three different solutions mimicking physiological environment, i.e. Hanks' Balance Salt Solution (HBSS), Dulbecco's modified Eagles' medium (DMEM) and DMEM with 10 % of fetal bovine serum (DMEM + 10 % FBS). Morphological characterizations, electrochemical tests, weight loss, and ion release measurements show that the corrosion mechanism is significantly affected by the physiological solution. In HBSS a phosphate-based conversion layer forms resulting to significantly slow down the corrosion rate, while in DMEM an intergranular corrosion occurs. The latter is hindered due to the presence of proteins from the fetal bovine serum in DMEM+FBS. The main cathodic process is oxygen reduction in all physiological media. Direct estimate of corrosion rate by gravimetric measurements revealed that zinc dissolution becomes very slow after two weeks of immersion in the employed physiological thus suggesting that zinc is not suitable for the fabrication of biodegradable implants in static fluidic condition.

Pupillo, D., Di Franco, F., Iannucci, L., Grassini, S., Virtanen, S., Santamaria, M. (2025). Following Zn corrosion during long term immersion test in physiological solutions to establish the potential of zinc as biodegradable prosthetic material. ELECTROCHIMICA ACTA, 531 [10.1016/j.electacta.2025.146411].

Following Zn corrosion during long term immersion test in physiological solutions to establish the potential of zinc as biodegradable prosthetic material

Pupillo D.;Di Franco F.
;
Santamaria M.
2025-05-06

Abstract

Corrosion behaviour of commercially pure Zn during immersion up to 4 weeks is studied in three different solutions mimicking physiological environment, i.e. Hanks' Balance Salt Solution (HBSS), Dulbecco's modified Eagles' medium (DMEM) and DMEM with 10 % of fetal bovine serum (DMEM + 10 % FBS). Morphological characterizations, electrochemical tests, weight loss, and ion release measurements show that the corrosion mechanism is significantly affected by the physiological solution. In HBSS a phosphate-based conversion layer forms resulting to significantly slow down the corrosion rate, while in DMEM an intergranular corrosion occurs. The latter is hindered due to the presence of proteins from the fetal bovine serum in DMEM+FBS. The main cathodic process is oxygen reduction in all physiological media. Direct estimate of corrosion rate by gravimetric measurements revealed that zinc dissolution becomes very slow after two weeks of immersion in the employed physiological thus suggesting that zinc is not suitable for the fabrication of biodegradable implants in static fluidic condition.
6-mag-2025
Settore ICHI-01/A - Chimica fisica applicata
Pupillo, D., Di Franco, F., Iannucci, L., Grassini, S., Virtanen, S., Santamaria, M. (2025). Following Zn corrosion during long term immersion test in physiological solutions to establish the potential of zinc as biodegradable prosthetic material. ELECTROCHIMICA ACTA, 531 [10.1016/j.electacta.2025.146411].
File in questo prodotto:
File Dimensione Formato  
2025_ElActa_Zn_corrosion_mechanism.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 5.63 MB
Formato Adobe PDF
5.63 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/706881
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact