This study investigates the thermal performance of a hydroponic roof system as an alternative strategy to an extensive green roof taking as a case study a prefabricated building module situated in the Mediterranean climate of Catania (Italy). Through dynamic simulations carried out with TRNSYS, the research compares the thermal behaviour of a hydroponic roof, an extensive green roof and a lightweight roof with the aim of understanding the effectiveness of the hydroponic solution in reducing the peak roof internal surface temperature and incoming heat flux. The findings indicate that a hydroponic roof system can reduce the peak value of the internal roof surface temperature of 2.7°C and delay by more than 10 hours the peak of the incoming heat flow, which is almost halved with respect to the lightweight roof solution.

Nocera, F., Costanzo, V., Detommaso, M., Evola, G., Mistretta, M., Longo, S. (2026). A Preliminary Investigation on the Thermal Performance of a Hydroponic Roof System in Mediterranean Climate. In SMART INNOVATION, SYSTEMS AND TECHNOLOGIES - Sustainability in energy and buildings 2024 (pp. 147-156) [10.1007/978-981-96-5069-9_13].

A Preliminary Investigation on the Thermal Performance of a Hydroponic Roof System in Mediterranean Climate

Longo S.
2026-01-01

Abstract

This study investigates the thermal performance of a hydroponic roof system as an alternative strategy to an extensive green roof taking as a case study a prefabricated building module situated in the Mediterranean climate of Catania (Italy). Through dynamic simulations carried out with TRNSYS, the research compares the thermal behaviour of a hydroponic roof, an extensive green roof and a lightweight roof with the aim of understanding the effectiveness of the hydroponic solution in reducing the peak roof internal surface temperature and incoming heat flux. The findings indicate that a hydroponic roof system can reduce the peak value of the internal roof surface temperature of 2.7°C and delay by more than 10 hours the peak of the incoming heat flow, which is almost halved with respect to the lightweight roof solution.
2026
Nocera, F., Costanzo, V., Detommaso, M., Evola, G., Mistretta, M., Longo, S. (2026). A Preliminary Investigation on the Thermal Performance of a Hydroponic Roof System in Mediterranean Climate. In SMART INNOVATION, SYSTEMS AND TECHNOLOGIES - Sustainability in energy and buildings 2024 (pp. 147-156) [10.1007/978-981-96-5069-9_13].
File in questo prodotto:
File Dimensione Formato  
Paper_.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 7.32 MB
Formato Adobe PDF
7.32 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/697596
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact