New psychoactive substances (NPS) are uncontrolled analogues of existing drugs or newly synthesized chemicals that exhibit psychopharmacological effects. Due to their diverse nature, composition, and increasing prevalence, they present significant challenges to the healthcare system and drug control policies. In response, healthcare system laboratories have developed analytical methods to detect NPS in biological samples. As a Regional Reference Centre, the Sicilian CRQ Laboratory (Regional Laboratory for Quality Control) developed and conducted an External Quality Assessment (EQA) study to assess, in collaboration with the Istituto Superiore di Sanita` (ISS), the ability of different Italian laboratories to identify NPS and traditional drugs of abuse (DOA) in biological matrices. Two blood samples were spiked with substances from various drug classes, including synthetic cannabinoids, cathinones, synthetic opiates, and benzodiazepines, at concentrations ranging from 2 to 10 ng/mL. The blood samples were freeze-dried to ensure the stability of DOA and NPS. Twenty-two laboratories from the Italian healthcare system participated in this assessment. The information provided by the laboratories during the registration in an in-house platform included a general description of the laboratory, analytical technique, and the chosen panels of analytes. The same platform was employed to collect and statistically analyze the data and record laboratory feedback and comments. The evaluation of the results revealed that the participating laboratories employed three different techniques for analyzing the samples: GC-MS, LC-MS, and immunoenzymatic methods. Approximately 90 % of the laboratories utilized LC-MS techniques. Around 40 % of false negative results were obtained, with the worst results in the identification of 5-chloro AB PINACA. The results showed that laboratories that used LC-MS methods obtained better specificity and sensitivity compared to the laboratories using other techniques. The results obtained from this first assessment underscore the importance of external quality control schemes in identifying the most effective analytical techniques for detecting trace molecules in biological matrices. Since the judicial authorities have not yet established cut-off values for NPS, this EQA will enable participating laboratories to share their analytical methods and expertise, aiming to establish common criteria for NPS identification.

Di Gaudio, F., Giaccone, V., Cucina, A., Indelicato, S., Raso, M., Brunacci, G., et al. (2024). Technical and health governance aspects of the external quality assessment system for classical and new psychoactive substances analysis testing in blood. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 245 [10.1016/j.jpba.2024.116175].

Technical and health governance aspects of the external quality assessment system for classical and new psychoactive substances analysis testing in blood

Di Gaudio F.
;
Cucina A.
;
Lundari A.;
2024-08-01

Abstract

New psychoactive substances (NPS) are uncontrolled analogues of existing drugs or newly synthesized chemicals that exhibit psychopharmacological effects. Due to their diverse nature, composition, and increasing prevalence, they present significant challenges to the healthcare system and drug control policies. In response, healthcare system laboratories have developed analytical methods to detect NPS in biological samples. As a Regional Reference Centre, the Sicilian CRQ Laboratory (Regional Laboratory for Quality Control) developed and conducted an External Quality Assessment (EQA) study to assess, in collaboration with the Istituto Superiore di Sanita` (ISS), the ability of different Italian laboratories to identify NPS and traditional drugs of abuse (DOA) in biological matrices. Two blood samples were spiked with substances from various drug classes, including synthetic cannabinoids, cathinones, synthetic opiates, and benzodiazepines, at concentrations ranging from 2 to 10 ng/mL. The blood samples were freeze-dried to ensure the stability of DOA and NPS. Twenty-two laboratories from the Italian healthcare system participated in this assessment. The information provided by the laboratories during the registration in an in-house platform included a general description of the laboratory, analytical technique, and the chosen panels of analytes. The same platform was employed to collect and statistically analyze the data and record laboratory feedback and comments. The evaluation of the results revealed that the participating laboratories employed three different techniques for analyzing the samples: GC-MS, LC-MS, and immunoenzymatic methods. Approximately 90 % of the laboratories utilized LC-MS techniques. Around 40 % of false negative results were obtained, with the worst results in the identification of 5-chloro AB PINACA. The results showed that laboratories that used LC-MS methods obtained better specificity and sensitivity compared to the laboratories using other techniques. The results obtained from this first assessment underscore the importance of external quality control schemes in identifying the most effective analytical techniques for detecting trace molecules in biological matrices. Since the judicial authorities have not yet established cut-off values for NPS, this EQA will enable participating laboratories to share their analytical methods and expertise, aiming to establish common criteria for NPS identification.
1-ago-2024
Di Gaudio, F., Giaccone, V., Cucina, A., Indelicato, S., Raso, M., Brunacci, G., et al. (2024). Technical and health governance aspects of the external quality assessment system for classical and new psychoactive substances analysis testing in blood. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 245 [10.1016/j.jpba.2024.116175].
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0731708524002152-main.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 399.45 kB
Formato Adobe PDF
399.45 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/695519
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact