A data-driven reduced order model (ROM) based on a proper orthogonal decomposition-radial basis function (POD-RBF) approach is adopted in this paper for the analysis of blood flow dynamics in a patient-specific case of atrial fibrillation (AF). The full order model (FOM) is represented by incompressible Navier–Stokes equations, discretized with a finite volume (FV) approach. Both the Newtonian and the Casson’s constitutive laws are employed. The aim is to build a computational tool able to efficiently and accurately reconstruct the patterns of relevant hemodynamics indices related to the stasis of the blood in a physical parametrization framework including the cardiac output in the Newtonian case and also the plasma viscosity and the hematocrit in the non-Newtonian one. Many FOM-ROM comparisons are shown to analyze the performance of our approach as regards errors and computational speed-up.
Balzotti, C., Siena, P., Girfoglio, M., Stabile, G., Duenas-Pamplona, J., Sierra-Pallares, J., et al. (2024). A reduced order model formulation for left atrium flow: an atrial fibrillation case. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 23(4), 1411-1429 [10.1007/s10237-024-01847-1].
A reduced order model formulation for left atrium flow: an atrial fibrillation case
Girfoglio M.;
2024-05-16
Abstract
A data-driven reduced order model (ROM) based on a proper orthogonal decomposition-radial basis function (POD-RBF) approach is adopted in this paper for the analysis of blood flow dynamics in a patient-specific case of atrial fibrillation (AF). The full order model (FOM) is represented by incompressible Navier–Stokes equations, discretized with a finite volume (FV) approach. Both the Newtonian and the Casson’s constitutive laws are employed. The aim is to build a computational tool able to efficiently and accurately reconstruct the patterns of relevant hemodynamics indices related to the stasis of the blood in a physical parametrization framework including the cardiac output in the Newtonian case and also the plasma viscosity and the hematocrit in the non-Newtonian one. Many FOM-ROM comparisons are shown to analyze the performance of our approach as regards errors and computational speed-up.| File | Dimensione | Formato | |
|---|---|---|---|
|
s10237-024-01847-1.pdf
accesso aperto
Tipologia:
Versione Editoriale
Dimensione
3.27 MB
Formato
Adobe PDF
|
3.27 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.