The development of highly sensitive and selective biosensors is crucial for early cancer diagnosis. This study presents a novel plas- monic nanoantenna-based sensor, designed to detect cancer biomarkers in the 1–10 THz range. The Hole V-Fork nanoantenna, fabricated in gold with a symmetrical structure composed of two arms with three segments each, exhibits resonance frequencies at 1.5 THz, 2.6 THz, and 3.8 THz, with a maximum peak absorption of -78 dB. A thorough parametric anal- ysis identified an optimal geometric configuration with a 62.86 μm arm length, 30.11 μm width, 200 nm thickness, and 60 nm gap, ensuring high directivity and enhanced sensing capabilities. Additionally, integrating a 3 nm graphene layer between the gold and silicon substrate introduced tunability, effectively shifting the resonance frequency and improving the sensor’s adaptability. A 4x4 nanoantenna array was designed and simulated, maintaining stable resonance frequencies while enhancing sensitivity and signal strength. Compared to the conventional Bowtie nanoan- tenna, the Hole V-Fork structure demonstrated superior impedance matching, stronger absorption, and better directivity. Sensitivity analysis using collagen as an analyte revealed a resonance shift corresponding to an average sensitivity of 607 GHz/RIU for the array configuration. The nanoantenna performance was experimentally validated using Fourier-transform infrared spectroscopy (FTIR), confirming its potential for detecting minute biomolecule concentrations. Due to its scalability, high sensitivity, and frequency tunability, the Hole V-Fork nanoantenna constitutes a significant advancement in THz plasmonic biosensing. Its ability to detect cancer biomarkers with high precision positions it as a promising candidate for non-invasive, next-generation biomedical diagnostics.

Scalici, M., Scarpulla, S., Livreri, P. (2025). A Novel Plasmonic Nanoantenna-Based Sensor with Graphene Tuning for Cancer Biomarker Detection. IEEE SENSORS JOURNAL, 25(16), 30622-30632 [10.1109/JSEN.2025.3586814].

A Novel Plasmonic Nanoantenna-Based Sensor with Graphene Tuning for Cancer Biomarker Detection

Marco Scalici;Samuele Scarpulla;Patrizia Livreri
2025-08-01

Abstract

The development of highly sensitive and selective biosensors is crucial for early cancer diagnosis. This study presents a novel plas- monic nanoantenna-based sensor, designed to detect cancer biomarkers in the 1–10 THz range. The Hole V-Fork nanoantenna, fabricated in gold with a symmetrical structure composed of two arms with three segments each, exhibits resonance frequencies at 1.5 THz, 2.6 THz, and 3.8 THz, with a maximum peak absorption of -78 dB. A thorough parametric anal- ysis identified an optimal geometric configuration with a 62.86 μm arm length, 30.11 μm width, 200 nm thickness, and 60 nm gap, ensuring high directivity and enhanced sensing capabilities. Additionally, integrating a 3 nm graphene layer between the gold and silicon substrate introduced tunability, effectively shifting the resonance frequency and improving the sensor’s adaptability. A 4x4 nanoantenna array was designed and simulated, maintaining stable resonance frequencies while enhancing sensitivity and signal strength. Compared to the conventional Bowtie nanoan- tenna, the Hole V-Fork structure demonstrated superior impedance matching, stronger absorption, and better directivity. Sensitivity analysis using collagen as an analyte revealed a resonance shift corresponding to an average sensitivity of 607 GHz/RIU for the array configuration. The nanoantenna performance was experimentally validated using Fourier-transform infrared spectroscopy (FTIR), confirming its potential for detecting minute biomolecule concentrations. Due to its scalability, high sensitivity, and frequency tunability, the Hole V-Fork nanoantenna constitutes a significant advancement in THz plasmonic biosensing. Its ability to detect cancer biomarkers with high precision positions it as a promising candidate for non-invasive, next-generation biomedical diagnostics.
ago-2025
Settore IINF-01/A - Elettronica
Scalici, M., Scarpulla, S., Livreri, P. (2025). A Novel Plasmonic Nanoantenna-Based Sensor with Graphene Tuning for Cancer Biomarker Detection. IEEE SENSORS JOURNAL, 25(16), 30622-30632 [10.1109/JSEN.2025.3586814].
File in questo prodotto:
File Dimensione Formato  
A_Novel_Plasmonic_Nanoantenna-Based_Sensor_With_Graphene_Tuning_for_Cancer_Biomarker_Detection.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 3.35 MB
Formato Adobe PDF
3.35 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/684903
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact