Photoacoustic imaging is an emerging imaging technique with application in early melanoma diagnosis, leveraging a laser pulse depositing a dose of energy into an optical absorber, such as melanin. This promising approach aims at detecting the morphological characteristics of a biological sample at depths that cannot be observed by conventional optical techniques. However, the technological immaturity of the sensor limits the spatial resolution, hence the performances of the system in early-stage melanoma diagnosis. In order to address this issue, this paper examines the scaling potential for Ultra-High Frequency Ultrasound PVDF-based sensors, which operate at (50-100 MHz) frequencies and which require a significant miniaturization as their acoustic performance depends on the ratio between their sizes and signal wavelength. The trade-offs between image quality, sensor channel directivity and system noise are discussed reporting simulation results for different μm sensor sizes on imaging performance.

Vallicelli E.A., Chirico G., Ferrara A.M., Baig M.H., Marrale M., Stevenazzi L., et al. (2024). Ultra-High Frequency Photoacoustic Sensor Design for Early Stage Melanoma Diagnosis. IEEE SENSORS JOURNAL, 01-04 [10.1109/SENSORS60989.2024.10784936].

Ultra-High Frequency Photoacoustic Sensor Design for Early Stage Melanoma Diagnosis

Marrale M.;
2024-12-17

Abstract

Photoacoustic imaging is an emerging imaging technique with application in early melanoma diagnosis, leveraging a laser pulse depositing a dose of energy into an optical absorber, such as melanin. This promising approach aims at detecting the morphological characteristics of a biological sample at depths that cannot be observed by conventional optical techniques. However, the technological immaturity of the sensor limits the spatial resolution, hence the performances of the system in early-stage melanoma diagnosis. In order to address this issue, this paper examines the scaling potential for Ultra-High Frequency Ultrasound PVDF-based sensors, which operate at (50-100 MHz) frequencies and which require a significant miniaturization as their acoustic performance depends on the ratio between their sizes and signal wavelength. The trade-offs between image quality, sensor channel directivity and system noise are discussed reporting simulation results for different μm sensor sizes on imaging performance.
17-dic-2024
Settore PHYS-06/A - Fisica per le scienze della vita, l'ambiente e i beni culturali
Vallicelli E.A., Chirico G., Ferrara A.M., Baig M.H., Marrale M., Stevenazzi L., et al. (2024). Ultra-High Frequency Photoacoustic Sensor Design for Early Stage Melanoma Diagnosis. IEEE SENSORS JOURNAL, 01-04 [10.1109/SENSORS60989.2024.10784936].
File in questo prodotto:
File Dimensione Formato  
Ultra-High_Frequency_Photoacoustic_Sensor_Design_for_Early_Stage_Melanoma_Diagnosis.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 2.24 MB
Formato Adobe PDF
2.24 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/675003
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact