Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Archivio istituzionale della ricerca dell'Università degli Studi di Palermo
Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.
Halim A.A., Abreu P., Aglietta M., Allison P., Allekotte I., Cheminant K.A., et al. (2023). AugerPrime surface detector electronics. JOURNAL OF INSTRUMENTATION, 18(10) [10.1088/1748-0221/18/10/P10016].
AugerPrime surface detector electronics
Halim A. A.
;Abreu P.;Aglietta M.;Allison P.;Allekotte I.;Cheminant K. A.;Almela A.;Aloisio R.;Alvarez-Muniz J.;Yebra J. A.;Anastasi G. A.;Anchordoqui L.;Andrada B.;Andringa S.;Anukriti;Aramo C.;Ferreira P. R. A.;Arnone E.;Velazquez J. C. A.;Assiro R.;Assis P.;Avila G.;Avocone E.;Badescu A. M.;Bakalova A.;Barbato F.;Mocellin A. B.;Beatty J. J.;Becker K. H.;Bellido J. A.;Berat C.;Bertaina M. E.;Bhatta G.;Bianciotto M.;Biermann P. L.;Binet V.;Bismark K.;Bister T.;Biteau J.;Blazek J.;Bleve C.;Blumer J.;Bohacova M.;Boncioli D.;Bonifazi C.;Arbeletche L. B.;Borodai N.;Brack J.;Orchera P. G. B.;Briechle F. L.;Bueno A.;Buitink S.;Buscemi M.;Busken M.;Bwembya A.;Caballero-Mora K. S.;Cabana-Freire S.;Caccianiga L.;Caruso R.;Castellina A.;Catalani F.;Cataldi G.;Cazon L.;Cerda M.;Cermenati A.;Chinellato J. A.;Chudoba J.;Chytka L.;Clay R. W.;Cerutti A. C. C.;Colalillo R.;Coleman A.;Coluccia M. R.;Conceicao R.;Condorelli A.;Consolati G.;Conte M.;Convenga F.;dos Santos D. C.;Costa P. J.;Covault C. E.;Cristinziani M.;Sanchez C. S. C.;Dasso S.;Daumiller K.;Dawson B. R.;de Almeida R. M.;de Jesus J.;de Jong S. J.;de Mello Neto J. R. T.;De Mitri I.;de Oliveira J.;de Oliveira Franco D.;de Palma F.;de Souza V.;de Souza de Errico B. P.;De Vito E.;Del Popolo A.;Deligny O.;Denner N.;Deval L.;di Matteo A.;Dobre M.;Dobrigkeit C.;D'Olivo J. C.;Domingues Mendes L. M.;dos Anjos J. C.;dos Anjos R. C.;Ebr J.;Ellwanger F.;Emam M.;Engel R.;Epicoco I.;Erdmann M.;Etchegoyen A.;Evoli C.;Falcke H.;Farmer J.;Farrar G.;Fauth A. C.;Fazzini N.;Feldbusch F.;Fenu F.;Fernandes A.;Fick B.;Figueira J. M.;Filipcic A.;Fitoussi T.;Flaggs B.;Fodran T.;Fujii T.;Fuster A.;Galea C.;Galelli C.;Garcia B.;Gaudu C.;Gemmeke H.;Gesualdi F.;Gherghel-Lascu A.;Ghia P. L.;Giaccari U.;Glombitza J.;Gobbi F.;Gollan F.;Golup G.;Gomez Berisso M.;Gomez Vitale P. F.;Gongora J. P.;Gonzalez J. M.;Gonzalez N.;Goos I.;Gora D.;Gorgi A.;Gottowik M.;Grubb T. D.;Guarino F.;Guedes G. P.;Guido E.;Hahn S.;Hamal P.;Hampel M. R.;Hansen P.;Harari D.;Harvey V. M.;Haungs A.;Hebbeker T.;Hojvat C.;Horandel J. R.;Horvath P.;Hrabovsky M.;Huege T.;Insolia A.;Isar P. G.;Janecek P.;Johnsen J. A.;Jurysek J.;Kampert K. H.;Keilhauer B.;Khakurdikar A.;Covilakam V. V. K.;Klages H. O.;Kleifges M.;Knapp F.;Kunka N.;Lago B. L.;Lagorio E.;Langner N.;de Oliveira M. A. L.;Lema-Capeans Y.;Lenok V.;Letessier-Selvon A.;Lhenry-Yvon I.;Lopes L.;Lu L.;Luce Q.;Lundquist J. P.;Payeras A. M.;Majercakova M.;Mandat D.;Manning B. C.;Mantsch P.;Marafico S.;Mariani F. M.;Mariazzi A. G.;Maris I. C.;Marsella G.;Martello D.;Martinelli S.;Bravo O. M.;Martins M. A.;Mathes H. J.;Matthews J.;Matthiae G.;Mayotte E.;Mayotte S.;Mazur P. O.;Medina-Tanco G.;Meinert J.;Melo D.;Menshikov A.;Merx C.;Michal S.;Micheletti M. I.;Miramonti L.;Mollerach S.;Montanet F.;Morejon L.;Morello C.;Mulrey K.;Mussa R.;Namasaka W. M.;Negi S.;Nellen L.;Nguyen K.;Trung T. N.;Nicora G.;Niechciol M.;Nitz D.;Nosek D.;Novotny V.;Nozka L.;Nucita A.;Nunez L. A.;Oliveira C.;Palatka M.;Pallotta J.;Panja S.;Parente G.;Paulsen T.;Pawlowsky J.;Pech M.;Pekala J.;Pelayo R.;Pereira L. A. S.;Martins E. E. P.;Armand J. P.;Bertolli C. P.;Perrone L.;Petrera S.;Petrucci C.;Pierog T.;Pimenta M.;Platino M.;Pont B.;Pothast M.;Pourmohammad Shahvar M.;Privitera P.;Prouza M.;Puyleart A.;Querchfeld S.;Rautenberg J.;Ravignani D.;Akim J. V. R.;Reininghaus M.;Ridky J.;Riehn F.;Risse M.;Rizi V.;de Carvalho W. R.;Rodriguez E.;Rojo J. R.;Roncoroni M. J.;Rossoni S.;Roth M.;Roulet E.;Rovero A. C.;Ruehl P.;Saftoiu A.;Saharan M.;Salamida F.;Salazar H.;Salina G.;Gomez J. D. S.;Sanchez F.;Santos E. M.;Santos E.;Sarazin F.;Sarmento R.;Sato R.;Savina P.;Schafer C. M.;Scherini V.;Schieler H.;Schimassek M.;Schimp M.;Schmidt D.;Scholten O.;Schoorlemmer H.;Schovanek P.;Schroder F. G.;Schulte J.;Schulz T.;Sciutto S. J.;Scornavacche M.;Segreto A.;Sehgal S.;Shivashankara S. U.;Sigl G.;Silli G.;Sima O.;Simon F.;Smau R.;Smida R.;Sommers P.;Soriano J. F.;Squartini R.;Stadelmaier M.;Stanic S.;Stasielak J.;Stassi P.;Strahnz S.;Straub M.;Suomijarvi T.;Supanitsky A. D.;Svozilikova Z.;Szadkowski Z.;Tairli F.;Tapia A.;Taricco C.;Timmermans C.;Tkachenko O.;Tobiska P.;Peixoto C. J. T.;Tome B.;Torres Z.;Travaini A.;Travnicek P.;Trimarelli C.;Tueros M.;Unger M.;Vaclavek L.;Vacula M.;Galicia J. F. V.;Valore L.;Varela E.;Vasquez-Ramirez A.;Veberic D.;Ventura C.;Quispe I. D. V.;Verzi V.;Vicha J.;Vink J.;Vlastimil J.;Vorobiov S.;Watanabe C.;Watson A. A.;Weindl A.;Wiencke L.;Wilczynski H.;Wittkowski D.;Wundheiler B.;Yue B.;Yushkov A.;Zapparrata O.;Zas E.;Zavrtanik D.;Zavrtanik M.
2023-10-17
Abstract
Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/667645
Citazioni
ND
0
1
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.