Aims: To evaluate safety and results of the Freepac drug-eluting balloon (DEB) technology for the treatment of chronic femoropopliteal steno-occlusions. Methods and results: In a multicentre registry we enrolled 66 patients with symptomatic femoropopliteal stenosis and/or occlusion <15 cm (Rutherford stages 2 to 4). Patients were treated first with an undersized uncoated balloon and then with an appropriate sized DEB. In case of unsatisfactory results, nitinol stents were implanted. Clinical evaluations and echo-duplex were performed at baseline, at discharge, and at three months after intervention. Procedural success was 100%. Stents were implanted in 10.8% of the patients. At three months follow-up, the mean ankle-brachial index (ABI) significantly improved from 0.58 ± 0.13 to 0.82 ± 0.25, thus resulting in a Rutherford class improvement (p <0.01) and amelioration of the claudication distance (102 ± 87 vs. 403 ± 160 meters) (p<0.001). No serious adverse events occurred during the follow-up. Conclusions: The results of this registry demonstrate the safety of mediated paclitaxel elution for the prevention of restenosis in the superficial femoral and popliteal arteries after angioplasty. This technique was associated with encouraging results in terms of clinical improvement as well as a lack of adverse events, including target lesion revascularisation, at three months.

Micari A, C.A. (2011). A new paclitaxel-eluting balloon for angioplasty of femoropopliteal obstructions: acute and midterm results. EuroIntervention. EUROINTERVENTION, 7 Suppl K, 77-82 [10.4244/EIJV7SKA14].

A new paclitaxel-eluting balloon for angioplasty of femoropopliteal obstructions: acute and midterm results. EuroIntervention.

Vadalà G;
2011-05-01

Abstract

Aims: To evaluate safety and results of the Freepac drug-eluting balloon (DEB) technology for the treatment of chronic femoropopliteal steno-occlusions. Methods and results: In a multicentre registry we enrolled 66 patients with symptomatic femoropopliteal stenosis and/or occlusion <15 cm (Rutherford stages 2 to 4). Patients were treated first with an undersized uncoated balloon and then with an appropriate sized DEB. In case of unsatisfactory results, nitinol stents were implanted. Clinical evaluations and echo-duplex were performed at baseline, at discharge, and at three months after intervention. Procedural success was 100%. Stents were implanted in 10.8% of the patients. At three months follow-up, the mean ankle-brachial index (ABI) significantly improved from 0.58 ± 0.13 to 0.82 ± 0.25, thus resulting in a Rutherford class improvement (p <0.01) and amelioration of the claudication distance (102 ± 87 vs. 403 ± 160 meters) (p<0.001). No serious adverse events occurred during the follow-up. Conclusions: The results of this registry demonstrate the safety of mediated paclitaxel elution for the prevention of restenosis in the superficial femoral and popliteal arteries after angioplasty. This technique was associated with encouraging results in terms of clinical improvement as well as a lack of adverse events, including target lesion revascularisation, at three months.
mag-2011
Micari A, C.A. (2011). A new paclitaxel-eluting balloon for angioplasty of femoropopliteal obstructions: acute and midterm results. EuroIntervention. EUROINTERVENTION, 7 Suppl K, 77-82 [10.4244/EIJV7SKA14].
File in questo prodotto:
File Dimensione Formato  
EuroInt_A new paclitaxel-eluting balloon for angioplasty of femoropopliteal obstructions- acute and midterm results.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 808.74 kB
Formato Adobe PDF
808.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/666924
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 27
social impact