Chemically modified pericardium is commonly used in the fabrication of bioprosthetic heart valves. This material exhibits non-linear elastic behaviour and, as for most other biological soft tissues, it is orthotropic in its extensibility. The influence of the natural orthotropy of pericardium on the mechanical behaviour of pericardial heart valves during the whole cardiac cycle has been studied, using the finite element method. A model of the leaflet of a bicuspid valve has been created, defining the material of the tissue as orthotropic non-linear elastic. Two preferential orthogonal orientations of the tissue have been analysed (axial and circumferential). The results show that even a small amount of orthotropy (an orthotropy index of 1.5 has been used) can significantly affect the mechanical behaviour of the valve, and that an appropriate orientation of the fibres can contribute to optimizing the stress distribution in the leaflets.

Burriesci G., Howard I.C., Patterson E.A. (1999). Influence of anisotropy on the mechanical behaviour of bioprosthetic heart valves. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 23(6), 203-215 [10.1080/030919099294050].

Influence of anisotropy on the mechanical behaviour of bioprosthetic heart valves

Burriesci G.
Primo
;
1999-07-09

Abstract

Chemically modified pericardium is commonly used in the fabrication of bioprosthetic heart valves. This material exhibits non-linear elastic behaviour and, as for most other biological soft tissues, it is orthotropic in its extensibility. The influence of the natural orthotropy of pericardium on the mechanical behaviour of pericardial heart valves during the whole cardiac cycle has been studied, using the finite element method. A model of the leaflet of a bicuspid valve has been created, defining the material of the tissue as orthotropic non-linear elastic. Two preferential orthogonal orientations of the tissue have been analysed (axial and circumferential). The results show that even a small amount of orthotropy (an orthotropy index of 1.5 has been used) can significantly affect the mechanical behaviour of the valve, and that an appropriate orientation of the fibres can contribute to optimizing the stress distribution in the leaflets.
9-lug-1999
Burriesci G., Howard I.C., Patterson E.A. (1999). Influence of anisotropy on the mechanical behaviour of bioprosthetic heart valves. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 23(6), 203-215 [10.1080/030919099294050].
File in questo prodotto:
File Dimensione Formato  
Influence of anisotropy on the mechanical behaviour of bioprosthetic heart valves.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 2.19 MB
Formato Adobe PDF
2.19 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/666567
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 36
social impact