An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DAΦNE e+e− collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.

Bosnar D., Abbene L., Amsler C., Artibani F., Bazzi M., Bragadireanu M., et al. (2024). A feasibility study of the measurement of kaonic lead X-rays at DAΦNE for the precise determination of the charged kaon mass. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1069 [10.1016/j.nima.2024.169966].

A feasibility study of the measurement of kaonic lead X-rays at DAΦNE for the precise determination of the charged kaon mass

Abbene L.;Buttacavoli A.;
2024-12-01

Abstract

An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DAΦNE e+e− collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
dic-2024
Settore PHYS-06/A - Fisica per le scienze della vita, l'ambiente e i beni culturali
Bosnar D., Abbene L., Amsler C., Artibani F., Bazzi M., Bragadireanu M., et al. (2024). A feasibility study of the measurement of kaonic lead X-rays at DAΦNE for the precise determination of the charged kaon mass. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1069 [10.1016/j.nima.2024.169966].
File in questo prodotto:
File Dimensione Formato  
Bosnar_NIMA_2024.pdf

Solo gestori archvio

Descrizione: Articolo
Tipologia: Versione Editoriale
Dimensione 1.14 MB
Formato Adobe PDF
1.14 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/662740
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact